ar8330t1780aa

Discharge air conditioning system

Typ ar · téma 83.30 · verze 0201 · 2019-06-27

Platí pro: Model NMB671.015/020/021/030/042 with code HKA (Konvekta ACX 602 air conditioning with roof heater)

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.30 Klimatizace — Řada 671 (modely 015, 020, 021, 030, 042)

EinPAS 39 Topení/větrání/chlazení › 39.15 Klimatizace › 39.15.5 Klimatizace kompletní — Řada 671 (modely 015, 020, 021, 030, 042)

AR83.30-T-1780AA

Discharge air conditioning system

12.06.2019

Model

NMB671.015/020/021/030/042

with code HKA (Konvekta ACX 602 air conditioning with roof heater)

Modification notes

10.03.2005

Open electromagnetic shutoff valve: Electric opening added

Operation step 1

Discharge air conditioning system

2

Pressure-side testing and filling valve

3

Suction side testing and filling valve

4

Intake side shutoff valve

T83.30-0061-06

Danger

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.

AS83.00-Z-0001-01A

Topical note

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Topical note

Procedure for a damaged or leaky air conditioning system

AH83.30-N-0004-01A

Notes on handling refrigerant R134a

AH83.30-N-0003-01A

1

Open electromagnetic shutoff valve


Manual opening

AR83.30-T-5460AA

Electric opening

AR83.30-T-5470BAC

2

Connect pressure and suction line of air conditioning vacuum and recycling unit to pressure side test and filling valve (2) and to intake side test and filling valve (3)

Observe operating instructions for air conditioning system vacuum and recycling unit.

3

Unscrew cover cap from intake side shutoff valve (4)

4

Screw in intake side shutoff valve (4) approx. 3 turns

The intake side test and filling valve (3) is opened by the screwing-in process.

5

Extract refrigerant via pressure side test and filling valve (2) and intake side test and filling valve (3)

Note the following:
Open valves of air conditioning vacuum and recycling unit slowly.
Pay attention to display message of air conditioning vacuum and recycling unit.
Extract refrigerant until there is no detectable weight increase to the extracted refrigerant.

6

After emptying the air conditioning system, unscrew intake side shutoff valve (4) up to the end stop

By unscrewing up to the end stop, the intake side test and filling valve (3) is closed.

7

Tighten cover cap on intake side shutoff valve (4)

8

Switch off air conditioning vacuum and recycling unit

9

Remove pressure and suction line of air conditioning vacuum and recycling unit