P83.30-3608-12
1 Fluid reservoir
2 Capacitor
3 Screw
4 Pressure plate
5 Bolts
| Removing | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
| Procedure for a damaged or leaky air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Notes on handling R134a refrigerant | ||
1 | Drain air conditioning (recycle) | Note quantity of extracted compressor oil. | |
Air conditioning draining, evacuating and charging equipment for refrigerant R134a | Air conditioner service unit R134a gotis://E_83_05.0 | ||
2.1 | Remove bottom engine compartment paneling at front | Model 211.042/043/056/061/065/070/ | |
Models 211.042/043/061/065/070/076/ | |||
2.2 | Remove bottom part of noise encapsulation at the front. | For models 211.004/006/016/023/026/028/ | |
3 | Remove screw/bolt (3) at fluid reservoir (1) and remove pressure plate (4) | ||
4 | Remove screws/bolts (5) and remove fluid reservoir (1) from condenser (2) | Seal line openings, otherwise dirt and moisture may penetrate. | |
Set of plugs for air conditioning system | |||
| Install | ||
5 | Replace fluid reservoir (1) | ||
6 | Insert fluid reservoir (1) in condenser (2) and screw in screws/bolts (5) | Replace sealing ring and moisten thread with compressor oil. | |
7 | Insert pressure plate (4) at fluid reservoir (1) and tighten with screw/bolt (3) | | |
8.1 | Install front lower engine compartment paneling | Model 211.042/043/056/061/065/070/ | |
Models 211.042/043/061/065/070/076/ | |||
8.2 | Install front bottom sections of soundproofing | For models 211.004/006/016/023/026/028/ | |
9 | Evacuate and fill air conditioning system | The refrigerant compressor may be damaged if the incorrect quantity of compressor oil is filled. | |
Air conditioning draining, evacuating and charging equipment for refrigerant R134a | Air conditioner service unit R134a gotis://E_83_05.0 | ||
Add noted quantity of compressor oil (new compressor oil) to air conditioning when filling, plus an additional quantity. | |||
10 | Check air conditioning system for leaks with leak detector | Air conditioning system leak detector |
Air conditioning
Refrigerant compressor
Odkazované dokumenty
- ah8330n000301a Pokyny k manipulaci s chladivem R134a
- ah8330n000401a Postup při poškozené, resp. netěsné klimatizaci
- ah8330n000501a Ochrana okruhu a součástí klimatizace při opravárenských pracích před vlhkostí
- ar6120p1105t
- ar9430p5300t
- as8300z000101a Nebezpečí exploze při svářečských nebo pájecích pracích na uzavřené klimatizaci. Nebezpečí otravy při vdechnutí přehřátých výparů chladiva. Nebezpečí poranění při kontaktu očí a kůže s tekutým chladivem