AR83.30-P-5520Q | Remove/install expansion valve | 26.6.07 |
MODEL 209
with CODE (580) Automatic air conditioning
with CODE (581) Comfort automatic air conditioning
P83.40-2625-09
1 Nut on expansion valve
2 Retaining plate
4 Firewall seal
3 Expansion valve
| Remove/install | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
| Procedure for a damaged or leaky air conditioning system | All models | |
| Notes on handling refrigerant R134a | All models fitted with air conditioning | |
Danger! | Risk of injury caused by moving parts that can pinch, crush or, in extreme cases even sever extremities. | Always remove ignition key when working on windshield wiper mechanism. | |
1 | Remove wiper system | ||
2 | Remove desiccant cartridge | Installation: Observe additional oil filling quantity after replacing parts. | |
Installation: The desiccant cartridge must be replaced after the refrigerant circuit has been opened. | |||
Model 209 with dryer at side | |||
Model 209 with dryer underneath | |||
3 | Unscrew expansion valve nut (1) | | |
4 | Remove pressure lines together with retaining plate (2) | Plug pressure line openings to avoid contamination. | |
Installation: Install new O-rings and moisten with compressor oil. | |||
| |||
5 | Unscrew screws (arrows) | Installation: In order to prevent offsetting of the pressure lines (thereby avoiding damage to the O-rings), tighten screws in an alternating pattern. | |
| |||
6 | Pull out expansion valve (3) | Seal openings with suitable plugs in order to avoid contamination. | |
Installation: Replace O-rings. Moisten threads and O-rings with compressor oil. | |||
| |||
7 | Make an incision in the firewall seal (4) | See illustration. | |
8 | Install in the reverse order | ||
9 | Check air conditioning system for proper function |
Air conditioning system
Number | Designation | Model | |
BA83.30-P-1001-01D | Nut on expansion valve | Nm | 8 |
BA83.30-P-1002-01D | Bolt for expansion valve | Nm | 10 |
Set of stop plugs
129 589 00 91 00
Odkazované dokumenty
- ah8330n000301a Pokyny k manipulaci s chladivem R134a
- ah8330n000401a Postup při poškozené, resp. netěsné klimatizaci
- ar8230p6400p Demontáž, montáž zařízení pro stírání
- ar8330p6521p
- ar8330p6521p
- ar8330p6521pa
- ar8330p6521pa
- as8230z000101a Nebezpečí poranění přivřením nebo přiskřípnutím, v extrémním případě amputace končetin při zásazích do mechaniky stěračů
- as8300z000101a Nebezpečí exploze při svářečských nebo pájecích pracích na uzavřené klimatizaci. Nebezpečí otravy při vdechnutí přehřátých výparů chladiva. Nebezpečí poranění při kontaktu očí a kůže s tekutým chladivem