1 | Nut on expansion valve |
2 | Retaining plate |
3 | Expansion valve |
4 | Seal |
P83.30-3368-06
| Remove/install | ||
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R134a | |||
Warning | Injury hazard from pinching and crushing, in extreme cases extremities can even be cut off when caught in windshield wiper mechanism. | When working on the windshield wiper mechanism, always switch off the ignition and store transmitter key outside of transmission range (at least 2 m). | |
1 | Remove wiper system | ||
2 | Remove receiver drier |
| |
As of 24.04.04 | |||
Installation: The receiver drier must be replaced each time the refrigerant circuit is opened in order to ensure proper operation of the air conditioning system. | |||
3 | Unscrew nut at expansion valve (1) | Nut on expansion valve | |
4 | Remove pressure lines together with retaining plate (2) | Seal openings in order to prevent soiling. | |
Installation: Replace sealing rings and moisten with compressor oil to prevent leaks. | |||
Record plug | |||
5 | Remove screws (arrows) | Installation: To prevent tilting, tighten screws alternately. | |
Bolt, expansion valve | |||
6 | Detach expansion valve (3) | Do not damage seal (4). It is only possible to replace the seal (4) after removing the air conditioner housing. Seal openings with suitable stop plugs to prevent foreign objects entering. | |
Installation: Replace sealing rings and moisten with compressor oil to prevent leaks. | |||
Record plug | |||
7 | Install in the reverse order | ||
8 | Check air conditioning system for proper function |
129 589 00 91 00
Record plug
Odkazované dokumenty
- ah8330n000301a Pokyny k manipulaci s chladivem R134a
- ah8330n000401a Postup při poškozené, resp. netěsné klimatizaci
- ah8330n000501a Ochrana okruhu a součástí klimatizace při opravárenských pracích před vlhkostí
- ar8230p6400p Demontáž, montáž zařízení pro stírání
- ar8330p6521p
- ar8330p6521p
- ar8330p6521pa
- ar8330p6521pa
- as8230z000101a Nebezpečí poranění přivřením nebo přiskřípnutím, v extrémním případě amputace končetin při zásazích do mechaniky stěračů
- as8300z000101a Nebezpečí exploze při svářečských nebo pájecích pracích na uzavřené klimatizaci. Nebezpečí otravy při vdechnutí přehřátých výparů chladiva. Nebezpečí poranění při kontaktu očí a kůže s tekutým chladivem