AR83.30-P-1760AK | Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks | 15.11.11 |
MODEL 169.0 /3, 245.2 (except 169.090, 245.286)
with CODE (580) Automatic air conditioning
with CODE (581) Comfort automatic air conditioning
P83.30-4013-08
Illustrated on model 169
1 Closure caps
2 Filling equipment connection
5 Low pressure pipe
3 High pressure pipe
4 Filling equipment connection
Drain | |||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
| Procedure for a damaged or leaky air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Notes on handling R134a refrigerant | ||
| Follow the manufacturer's instructions when operating the filling equipment | ||
1 | Open engine hood and secure against falling down | ||
2 | Unscrew closure caps (1) | ||
3 | Connect the filling equipment connection (2) to the filling connection of the high pressure line (3) and the filling equipment connection (4) to the filling connection for the low-pressure line (5) | Air conditioner service unit R134a gotis://E_83_05.0 | |
4 | Suction off refrigerant | Note down suctioned off compressor oil quantity. | |
Air conditioner service unit R134a gotis://E_83_05.0 | |||
Evacuate | |||
5.1 | Replace fluid reservoir | Only if refrigerant circuit has been opened. | |
6 | Clean refrigerant and evacuate air conditioning system | Air conditioner service unit R134a gotis://E_83_05.0 | |
Fill | |||
7 | Replace the quantity of compressor oil noted when evacuating the air conditioning system with new compressor oil and route back to the refrigerant circuit | If the wrong quantity of compressor oil is refilled then the refrigerant compressor may be damaged. | |
Additional oil filling quantities following installation of new refrigerant circuit components: | |||
Refrigerant compressor filling quantity | |||
Additional oil filling quantity following sudden draining of system (e.g. line ruptured) | |||
Additional oil filling quantity after replacing condenser | |||
Additional oil filling quantity after replacing evaporator | |||
Additional oil filling quantity after replacing fluid reservoir | |||
Additional oil filling quantity after replacing low-pressure line | |||
Additional oil filling quantity after replacing high-pressure line | |||
Additional oil filling quantity after replacing refrigerant compressor | |||
Additional oil filling quantity in case of detectable leakage | |||
Air conditioner service unit R134a gotis://E_83_05.0 | |||
8 | Charge air conditioning system | Capacity | |
Air conditioner service unit R134a gotis://E_83_05.0 | |||
9 | Perform pressure test on AC system | Air conditioner service unit R134a gotis://E_83_05.0 | |
10 | Connect the filling equipment connection (2) to the filling connection of the high pressure line (3) and the filling equipment connection (4) to the filling connection for the low-pressure line (5) | Air conditioning system leak detector | |
| Check | ||
11 | Check air conditioning system for leaks with leak detector | Air conditioning system leak detector | |
12 | Screw on closure caps (1) | ||
13 | Close engine hood |
Air conditioning system/automatic air conditioning
Number | Designation | Model | Model | Model | ||
BF83.00-P-1001-01D | Capacity | Refrigerant R134 a | g | 770 | 840 | 770 |
Specifications for Operating Fluids | Sheet | |||||
Air conditioning system/automatic air conditioning
Number | Designation | Model | Model | Model | ||
BF83.00-P-1001-01D | Capacity | Refrigerant R134 a | g | 770 | 840 | 770 |
Specifications for Operating Fluids | Sheet | |||||
Refrigerant compressor
Number | Designation | Model 169 | Model 245 | ||
BF83.55-P-1001-01F | Refrigerant compressor filling quantity | Compressor oil | cm3 | 120 | 120 |
Specifications for Operating Fluids | Sheet | ||||
BF83.55-P-1002-01F | Additional oil filling quantity following sudden draining of system (e.g. line ruptured) | Compressor oil | cm3 | 40 | 40 |
Specifications for Operating Fluids | Sheet | ||||
BF83.55-P-1003-01F | Additional oil filling quantity after replacing condenser | Compressor oil | cm3 | 20 | 20 |
Specifications for Operating Fluids | Sheet | ||||
BF83.55-P-1004-01F | Additional oil filling quantity after replacing evaporator | Compressor oil | cm3 | 40 | 40 |
Specifications for Operating Fluids | Sheet | ||||
BF83.55-P-1005-01F | Additional oil filling quantity after replacing fluid reservoir | Compressor oil | cm3 | 10 | 10 |
Specifications for Operating Fluids | Sheet | ||||
BF83.55-P-1006-01F | Additional oil filling quantity after replacing low-pressure line | Compressor oil | cm3 | 20 | 20 |
Specifications for Operating Fluids | Sheet | ||||
BF83.55-P-1007-01F | Additional oil filling quantity after replacing high-pressure line | Compressor oil | cm3 | 20 | 20 |
Specifications for Operating Fluids | Sheet | ||||
BF83.55-P-1008-01F | Additional oil filling quantity after replacing refrigerant compressor | Compressor oil | cm3 | 20 | 20 |
Specifications for Operating Fluids | Sheet | ||||
BF83.55-P-1009-01F | Additional oil filling quantity in case of detectable leakage | Compressor oil | cm3 | 20 | 20 |
Specifications for Operating Fluids | Sheet | ||||
Odkazované dokumenty
- ah8330n000301a Pokyny k manipulaci s chladivem R134a
- ah8330n000401a Postup při poškozené, resp. netěsné klimatizaci
- ah8330n000501a Ochrana okruhu a součástí klimatizace při opravárenských pracích před vlhkostí
- ar8330p6520ak
- as8300z000101a Nebezpečí exploze při svářečských nebo pájecích pracích na uzavřené klimatizaci. Nebezpečí otravy při vdechnutí přehřátých výparů chladiva. Nebezpečí poranění při kontaktu očí a kůže s tekutým chladivem