Model | 903.663 |
Minibus Sprinter Group, with rear air conditioning system SC1-9 | |
Model | 903.663 |
Minibus Sprinter Group, with rear air conditioning system SC4-10 | |
Model | 904.663 |
Minibus Sprinter Classic, with rear air conditioning system SC2-10 | |
Model | 904.663 |
Minibus Sprinter Classic, with rear air conditioning system SC3-11 with additional condenser | |
Model | 904.663 |
Minibus Sprinter Eco, with rear air conditioning system SC1-9 | |
Model | 904.663 |
Minibus Sprinter Group, with rear air conditioning system SC1-9 | |
Model | 904.663 |
Minibus Sprinter Group, with rear air conditioning system SC4-10 | |
Model | 904.663 |
Minibus Sprinter low floor, with rear air conditioning system SC2-10 | |
Model | 904.663 |
Minibus Sprinter low floor, with rear air conditioning system SC3-11 with additional condenser | |
Model | 904.663 |
Minibus Sprinter Tourist, with rear air conditioning system SC3-10 | |
Model | 904.663 |
Minibus Sprinter Tourist, with rear air conditioning system SC5-10 | |
Model | 905.613 |
Minibus Sprinter Classic 6 t, with rear air conditioning system SC3-11 with additional condenser | |
Model | 905.613 |
Minibus Sprinter low-floor 6 t, with rear air conditioning system SC3-11 with additional condenser |
1 | Refrigerant line |
2 | Filter drier |
3 | Refrigerant line |
4 | Securing clamp |
6 | Pressure switch connector |
D83.30-1113-12
| Remove/install | ||
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R134a | |||
1 | Drain air conditioning system | ||
2 | Detach pressure switch connector coupling (6) | ||
3 | Unscrew refrigerant lines (1 and 3) | ||
| |||
Plug openings. | |||
Installation: Install new sealing rings. Coat sealing rings with compressor oil before installation. | |||
Bolt, refrigerant line to filter drier | |||
Record plug | |||
4 | Release mounting clamp (4) and remove filter drier (2) | | |
Determine remaining quantity of compressor oil in removed filter drier (2). Fill same amount of new compressor oil into new filter drier (2). | |||
Total compressor oil filling capacity of air conditioning system (including AC compressor) | |||
5 | Install in the reverse order | ||
6 | Evacuate air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak | ||
Total filling capacity, refrigerant |
Air conditioning |
Number | Designation | Model 903.663, 904.663 with air conditioning system SC1-9 | Model 903.663, 904.663 with air conditioning system SC4-10 | ||
BF83.30-N-1002-01G | Total compressor oil filling capacity of air conditioning system (including AC compressor) | cm3 | 150 | 340 | |
Specifications for Operating Fluids, Sheet | |||||
Air conditioning |
Number | Designation | Model 904.663 with air conditioning system SC3-11 with additional condenser | Model 904.663 with roof air conditioning system Sütrak AC 111 | ||
BF83.30-N-1002-01G | Total compressor oil filling capacity of air conditioning system (including AC compressor) | cm3 | 220 | 500 | |
Specifications for Operating Fluids, Sheet | |||||
Air conditioning |
Number | Designation | Model 904.663 with air conditioning systemSC2-10 | Model 904.663 with air conditioning systemSC3-10 | ||
BF83.30-N-1002-01G | Total compressor oil filling capacity of air conditioning system (including AC compressor) | cm3 | 180 | 220 | |
Specifications for Operating Fluids, Sheet | |||||
Air conditioning |
Number | Designation | Model 904.663 with air conditioning systemSC5-10 | MODEL 905.613 with Hispacold roof air conditioningD5 | ||
BF83.30-N-1002-01G | Total compressor oil filling capacity of air conditioning system (including AC compressor) | cm3 | 500 | 460 | |
Specifications for Operating Fluids, Sheet | |||||
Air conditioning |
Number | Designation | Model 905.613 with air conditioning system SC3-11 with additional condenser | Model 905.613 with roof air conditioning system Sütrak AC 111 | ||
BF83.30-N-1002-01G | Total compressor oil filling capacity of air conditioning system (including AC compressor) | cm3 | 250 | 550 | |
Specifications for Operating Fluids, Sheet | |||||
129 589 00 91 00
Record plug
Odkazované dokumenty
- ah8330n000301a Pokyny k manipulaci s chladivem R134a
- ah8330n000401a Postup při poškozené, resp. netěsné klimatizaci
- ah8330n000501a Ochrana okruhu a součástí klimatizace při opravárenských pracích před vlhkostí
- ar8330m1760a
- ar8330m1760a
- as8300z000101a Nebezpečí exploze při svářečských nebo pájecích pracích na uzavřené klimatizaci. Nebezpečí otravy při vdechnutí přehřátých výparů chladiva. Nebezpečí poranění při kontaktu očí a kůže s tekutým chladivem
- bb0040p036200a Kompresorové oleje (specifikace 362.0)