Test values for exterior lighting
Number | Designation | Model 129 | ||
BE82.10-P-1001-01D | Pressure values for pneumatic headlamp range adjustment | Position 0 | mbar | 400 30 |
Position 1 | mbar | 290 30 | ||
Position 2 | mbar | 200 30 | ||
Position 3 | mbar | 50 30 | ||
201 589 13 21 00
Vacuum tester
P82.10-2144-01
1 The pressure for the headlamp range adjustment can be measured on the pressure valve block (4). The pressure valve block (4) is located in the right component compartment.
2 Allow engine to run.
3 Set headlamp range adjustment to individual positions and read off pressure values. If the nominal value is not reached, perform leakage test.
P82.10-2145-01
If the connection sockets are leaky they can be replaced by adapters (8). For this purpose separate pneumatic line (9) from control switch (7) and shorten by 50 mm. Install adapter (8) instead of cut connection socket and connect to hose connector (approx. 40 mm long).