AR82.10-D-4011A | Checking pneumatic headlamp range control | 31.7.96 |
MODELS 901.0 /3 /4, 902.0 /3 /4, 903.0 /3 /4, 904.0 /3 /4
D82.10-0015-05
1 Control switch
2 Right headlamp actuator
3 Left headlamp actuator
4 Vacuum connection
A Vacuum hose connector/black
B Vacuum hose connector/black-green
| Inspecting | ||
1 | Check headlamp adjustment, correct | ||
2 | Check adjustment range of headlamp range control | if applicable when adjustment values are not reached | |
3 | Check vacuum system for headlamp range control | ||
Nominal vacuum values | |||
| |||
When vacuum nominal values are not reached | |||
Check vacuum system for leakage | |||
When vacuum nominal values are reached | |||
4 | Check actuator for proper function |
Test values for exterior lighting
Number | Designation | Models | ||
BE82.10-N-1001-01B | Vacuum pneumatic headlamp range control | Position 0 | mbar | 500 (50) |
Position 1 | mbar | 400 (50) | ||
Position 2 | mbar | 200 (50) | ||
Position 3 | mbar | 100 (50) | ||
Vacuum tester
201 589 13 21 00