AR77.50-P-6763V | Remove/install paneling on C-pillar upper section for Vario roof | 12.10.09 |
MODEL 171.4
P77.50-2154-07
1 C-pillar cover
2 Outer C-pillar seal
5 C-pillar upper section
4 Wedge
P77.50-2155-09
1 C-pillar cover
5 C-pillar upper section
6 Sealing tape
7 Outer C-pillar stay
11 Inner C-pillar stay
12 Bead
13 Catch lug
8 Sealing section
9 Inner C-pillar seal
10 Cover stay
Modification notes
| Removing | ||
Danger! | Risk of injury caused by body parts being trapped or crushed when working on partially open Vario roof (stop mode) or in its closing area as a result of the Vario roof suddenly collapsing | Secure Vario roof with a suitable special tool. | |
1 | Move Vario roof to intermediate position and secure | Position of C-pillar top sections (1) approx. 75°. | |
| |||
2 | Knock C-pillar covering (1) up with suitable wedge (4) and plastic mallet and remove from C-pillar top section (5) | Carefully tap C-pillar covering (1) upward. Danger of breakage. | |
The C-pillar covering (1) can seat extremely tightly on the C-pillar top section (5) due to contact with sealant. | |||
| Install | ||
3.1 | Completely remove sealant residues from C-pillar covering (1) | Not when replacing C-pillar covering (1). | |
4 | Install sealing tape (6) on uppermost bead (12) of outer C-pillar stay (7) as shown | Form a ball of sealing tape (6) and press into uppermost bead (12). The uppermost bead (12) should be filled completely and flush. Do not touch sealing tape (6) with bare fingers. | |
121.5 mm butyl strip | |||
5 | Apply soap solution over entire length of outer C-pillar stay (7), inner C-pillar stay (11) and in area of inner C-pillar seal (9) located on the C-pillar covering (1) | Do not use antifriction agent containing solvents to prevent damaging inner C-pillar seal (9). | |
6 | Position C-pillar covering (1) with bottom edge approx. 10 mm above lower bead (12) in inner C-pillar stay (11) | Carefully slide C-pillar covering (1) onto C-pillar upper section (5). Danger of breakage. | |
7 | Arrest covering stay (10) with inner C-pillar stay (11) over entire length in direction of arrow (arrow A) | Ensure that the cover stay (10) is seated in the inner C-pillar seal (9) as shown. Slightly press C-pillar covering (1) in direction of arrow (arrow A) over entire length while sliding onto C-pillar top section (5). | |
8 | Firmly slide C-pillar covering (1) downward to C-pillar upper section (5) until the bottom edge of the C-pillar covering (1) is flush with the edge (arrow C) of the C-pillar upper section (5) | All retaining tabs (13) of the C-pillar covering (1) should be arrested on the outer C-pillar stay (7). | |
9 | Check seat of C-pillar covering (1) in inner C-pillar seal (9) | Check by pulling back sealing profile (8) on inner C-pillar seal (9). The lip (arrow B) should be upright in relation to the C-pillar covering (1) over the entire length | |
10 | Remove support for securing intermediate position of Vario roof and close Vario roof | |
Support
230 589 04 63 00
Repair materials
Number | Designation | Order number |
BR00.45-Z-1050-01A | Upper rear folding roof sealing | A 170 795 11 98 |
Odkazované dokumenty
- ar7750p300001v