ar6810d1030a

Removing and installing center section of instrument panel

Typ ar · téma 68.10 · verze 0100 · 1996-09-26

Platí pro: MODEL 667, 668, 670

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 68 Vnitřní výbava › 68.10 Přístrojová deska — Řada 667 · Řada 668 · Řada 670

EinPAS 37 Vnitřní výbava › 37.15 Přístrojová deska › 37.15.44 Přístrojová deska/zakrytí/obložení/nosník — Řada 667 · Řada 668 · Řada 670

AR68.10-D-1030A

Removing and installing center section of instrument panel

10.6.96

MODEL 667, 668, 670

Removing and installing center section of instrument panel

D68.10-0051-09

1 Hinge pin
2 Flap
3 Heater/ventilation knobs
4 Bulbs

9 Screw
10 Instrument panel cover
19 Stationary heater rotary switch
22 Engine cover

5 Stationary heater knob
6 Nut
7 Washer
8 Blower switch

Removing and installing center section of instrument panel

D68.10-0052-06

8 Blower switch
10 Instrument panel cover
11 Electrical connector
12 Cap
13 Electrical connector
14 Catch
15 Profile gasket
16 Air duct
17 Wiring harness
18 Cable guide
19 Stationary heater rotary switch
20 Lug
21 Recess
22 Engine cover

Removal, installation

1

Remove ground lead from battery

2

Remove engine cover (22)

3

Slide spring loaded hinge pins (1) for stowage compartment flap (2) back in direction of arrow and remove flap

4

Remove knobs for heater/ventilation (3)

When attaching the knobs do not damage bulbs (4) in switches.

5

Pull off stationary heater knob (5)

with warm heater stationary heater D5W code H12

6

Remove nut (6) and washer (7) from blower switch (8)

7

Remove nut (6) and washer (7) from stationary heater rotary switch (19)

with warm heater stationary heater D5W code H12

8

Unscrew screws (9)

9

Pull instrument panel cover (10) forward

Installation:
Ensure that profile gasket (15) is properly seated on air duct (16). The profile gasket must be pushed on up to the stop.

10

Separate electrical connectors for switch illumination (11) and pull wiring harness (17) out under cable guides (18).

11

Remove cap (12) from blower switch (8)

Installation:
Ensure that catch hooks are properly seated.

12

Release arresting device (14) on electrical connector (13) for blower switch and disconnect electrical connector.

Installation:
Ensure that catch hooks are seated properly.

13

Remove stationary heater rotary
switch (19)

with warm heater stationary heater D5W code H12

Installation:
Rotation lock: The lugs (20) in the rotary switch must engage in the recesses (21) in the cover.

14

Remove instrument panel cover

15

Reinstall in opposite order

16

Check for proper function