AR65.00-P-1000Q | Install base plates for roof rack | 15.11.11 |
MODEL 209.3## ## as of 000001 up to 052500
all have M6 threads
MODEL 209.3## ## as of 052501 up to 060000
some may have M6 threads
P65.00-2071-09
1 Base plates
3 Oris roof carrier
2 Washers
| Removing | ||
Danger! | Risk of poisoning caused by inhaling vapors or swallowing adhesive. Risk of injury caused by adhesive coming into contact with skin and eyes | Wear respiratory protection, protective gloves and safety glasses. Pour adhesive into suitable and appropriately marked containers only. | |
1 | Remove water repellent | ||
Assembly wedge | |||
2 | Cover repair area thoroughly with sheeting and adhesive tape. | ||
| Install | ||
3 | Install Oris (3) base plates (1) for roof carrier | ||
Use repair kit (contains 4 base plates (1) and 4 washers (2)). | |||
Betapower II (2-component electric cartridge gun) | |||
Tap set M7 | |||
Drill | |||
Wet/dry vacuum cleaner | |||
Repair kit | |||
4 | Clean repair areas | ||
5 | Install water repellent |
Mounting wedge
110 589 03 59 00
Repair materials
Number | Designation | Order number |
BR00.45-Z-1015-02A | Repair kit, glazing, installing window, 2-component adhesive | A 220 670 00 93 |
Odkazované dokumenty
- ar6500p100001q
- ar8885p2100q
- as0000z001601a Nebezpečí otravy při vdechnutí výparů nebo při požití lepidla. Nebezpečí poranění při kontaktu lepidla s kůží a očima