ar6110d572001b

Separate front floor in cab up to firewall

Typ ar · téma 61.10 · verze 0106 · 2006-07-25

Platí pro: MODEL 901.31 /32 /42 /61 /62, 902.31 /32 /41 /42 /61 /62, 903.01 /02 /31 /32 /41 /42 /61 /62, 904.01 /31 /32 /41 /42 /61 /62, 905.61 /62 MODEL 690.61 MODEL XD2, XD3, XD4, XD5, XD6, XD7 MODEL 903.62, 904.62 with CODE (ZU9) National version for Mexico

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 61 Spodní část vozidla › 61.10 Rámová podlaha — Řada 690 (modely 61*) · Řada 901 (modely 31*, 32*, 42*, 61*, 62*) · Řada 902 (modely 31*, 32*, 41*, 42*, 61*, 62*) · Řada 903 (modely 01*, 02*, 31*, 32*, 41*, 42*, 61*, 62*) · Řada 904 (modely 01*, 31*, 32*, 41*, 42*, 61*, 62*) · Řada 905 (modely 61*, 62*)

EinPAS 35 Karoserie/rám/montované díly › 35.32 Podvozek › 35.32.35 Podlahová skupina/žebroví podvozku — Řada 690 (modely 61*) · Řada 901 (modely 31*, 32*, 42*, 61*, 62*) · Řada 902 (modely 31*, 32*, 41*, 42*, 61*, 62*) · Řada 903 (modely 01*, 02*, 31*, 32*, 41*, 42*, 61*, 62*) · Řada 904 (modely 01*, 31*, 32*, 41*, 42*, 61*, 62*) · Řada 905 (modely 61*, 62*)

AR61.10-D-5720-01B

Separate front floor in cab up to firewall

Separate front floor in cab up to firewall

201 589 00 51 00

Spot weld cutter

Workshop equipment

WE58.40-Z-1001-03A

Drill (electric/pneumatic)

WE58.40-Z-1003-03A

Angle grinder (electric/pneumatic)

WE58.40-Z-1004-03A

Body saw (electric/pneumatic)

WE58.40-Z-1005-03A

Wet/dry vacuum cleaner

Separate front floor in cab up to firewall

D61.10-0137-12

1 Mark separation line (dotted line, 6) in center of front floor (1).

2 Mark separation lines (7, 19 and 20) with the following dimensions:

a = 490 mm,

b = 240 mm,

c = 90 mm measured from outer edge of cutout (arrow).

Separate front floor in cab up to firewall

D61.10-0138-06

3 Expose spot welds in area (B) of front floor (1) and cut out.

4 Expose spot welds in area (C) of front floor (1) and grind.

Separate front floor in cab up to firewall

D61.10-0139-12

5 Expose all spot welds of front floor (1) in shaded area up to separation lines (dotted lines 6, 7, 19 and 20) and cut out.

Separate front floor in cab up to firewall

D61.10-0140-06

6 Mark separation line (8) along bracket (9) on front floor (1).

Cutting depth in area of cross braces (10), of reinforcement bracket (9) and along separation line (20) should be max. 1 mm.

7 Separate front floor (1) along separation lines (6, 7, 8, 19 and 20).

Separate front floor in cab up to firewall

D61.10-0086-01

8 Expose spot welds on firewall in area (D) and cut out.