ar6110d572001a

Separating front floor in cab up to firewall

Typ ar · téma 61.10 · verze 0105 · 2006-07-26

Platí pro: MODEL 901.06 /36 /37 /46 /66 /67, 902.06 /07 /36 /37 /46 /47 /66 /67, 903.06 /07 /36 /37 /46 /47 /66 /67, 904.06 /36 /46 /66 MODEL 690.63 /64

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 61 Spodní část vozidla › 61.10 Rámová podlaha — Řada 690 (modely 63*, 64*) · Řada 901 (modely 06*, 36*, 37*, 46*, 66*, 67*) · Řada 902 (modely 06*, 07*, 36*, 37*, 46*, 47*, 66*, 67*) · Řada 903 (modely 06*, 07*, 36*, 37*, 46*, 47*, 66*, 67*) · Řada 904 (modely 06*, 36*, 46*, 66*)

EinPAS 35 Karoserie/rám/montované díly › 35.32 Podvozek › 35.32.35 Podlahová skupina/žebroví podvozku — Řada 690 (modely 63*, 64*) · Řada 901 (modely 06*, 36*, 37*, 46*, 66*, 67*) · Řada 902 (modely 06*, 07*, 36*, 37*, 46*, 47*, 66*, 67*) · Řada 903 (modely 06*, 07*, 36*, 37*, 46*, 47*, 66*, 67*) · Řada 904 (modely 06*, 36*, 46*, 66*)

AR61.10-D-5720-01A

Separating front floor in cab up to firewall

Separating front floor in cab up to firewall

201 589 00 51 00

Spot weld miller

Commercially available tools

Number

Designation

WH58.30-Z-1004-20A

Hot-air gun

Workshop equipment

WE58.40-Z-1001-03A

Drill (electric/pneumatic)

WE58.40-Z-1003-03A

Angle grinder (electric/pneumatic)

WE58.40-Z-1004-03A

Body saw (electric/pneumatic)

WE58.40-Z-1005-03A

Wet/dry vacuum cleaner

Separating front floor in cab up to firewall
Separating front floor in cab up to firewall

D61.10-0064-03

D61.10-0063-03

1 Mark separation line (6) in center of front floor (1).

Cut spot welds out through cargo space floor and floor panel in one step.

2 Expose spot welds in area (A) up to behind separating line (6) and cut out.

Separating front floor in cab up to firewall

D61.10-0065-06

3 Expose spot welds in area (B) of front floor (1) and cut out.

4 Expose spot welds in area (C) of front floor (1) and grind down.

Separating front floor in cab up to firewall

5 Expose all spot welds of front floor (1) in shaded area up to separation line (6) and cut out.

D61.10-0066-03

Separating front floor in cab up to firewall

D61.10-0067-06

6 Mark separation line (8) along bracket (9) on front floor (1)

Cutting depth in area of lateral struts (10) and reinforcement bracket (9) max. 1 mm.

7 Separate front floor (1) along separation lines (6 8).

Separating front floor in cab up to firewall

D61.10-0086-01

8 Expose spot welds at firewall in area (D) and cut out.