ar5530g000404b

Carry out teach-in process for scaling of oil level sensor

Typ ar · téma 55.30 · verze 0206 · 2011-09-14

Platí pro: MODEL 405.10 /12 /20 /22 with CODE (H63) Power hydraulics, closed circuit (125 l/min. 300 bar) with CODE (H64) Power hydraulics, open circuit (90 l/min. 280 bar) with CODE (H65) Power hydraulics with adjusting pump, closed circuit (125 l/min. 300 bar), open circuit (90 l/min. 280 bar)

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 55 Přídavné pohony, hydraulické a kloubové systémy › 55.30 Hydraulický pohon, hydraulická čerpadla — Řada 405 (modely 10*, 12*, 20*, 22*)

EinPAS 35 Karoserie/rám/montované díly › 35.70 Zvedací závěs/hydraulické zařízení › 35.70.12 Snímač/spínač/kabelový svazek — Řada 405 (modely 10*, 12*, 20*, 22*)

AR55.30-G-0004-04B

Carry out teach-in process for scaling of oil level sensor

Hydraulic drive, hydraulic pump

Number

Designation

Model
405.10/12/20/22 with power hydraulics
except code H97

Model
405.10/12/20/22 with power hydraulics
with code H97

BF55.30-N-1002-02A

Engine oil
SAE 10 W

Filling capacities for power hydraulics

Liters

60

-

Sheet

BB00.40-P-0228-00A

-

BF55.30-N-1006-02A

Panolin HLP synthetic 46 (HLP/HLP-D46, ISO-VG)

Filling capacities for power hydraulics

Liters

-

60

Carry out teach-in process for scaling of oil level sensor

G55.30-3354-01

1 Move in all hydraulic cylinders which are operated with power hydraulics.

No hydraulic cylinders may be moved outwards otherwise overfilling of the hydraulic oil reservoir (1) may occur.

2 Check oil level in hydraulic fluid reservoir (1), if necessary fill hydraulic fluid reservoir (1) with oil up to marking (2).

Except code (H97) Carboxylic acid ester for hydraulic system, use engine oil SAE 10 W.

With code (H97) Carboxylic acid ester for hydraulic system, use panolin HLP Synthetic 46 (HLP/HLP-D46, ISO-VG).

Carry out teach-in process for scaling of oil level sensor

G54.25-3459-71

3 Switch off ignition.

4 Press buttons (3, 4) at the same time and keep pressed, switch on ignition.

Keep buttons (3, 4) pressed until the LEDs above the zero scale and the LEDs in the third last field (arrow) of the bargraph (5) light up.

The teach-in process is active.

5 Press button (6) and observe the LEDs lighting up in the hydraulics output part (A23).

After pressing the button (6) the LED in the third-last field (arrow) of the bargraph (5) flashes on and off. After this the LED of the button (7) lights up.

6 Press button (7) and observe the LEDs lighting up in the bargraph (5).

A successful parameterizing is signaled by a brief running light in the bargraph (5). After this the LED above the zero scale and the LED in the third last field of the bargraph (5) lights up.

If the running light in the bar graph (5) does not appear, operation steps 3 to 6 must be repeated.

7 Switch off ignition.