ar5415p1255ea

Removing and installing fuse and relay box

Typ ar · téma 54.15 · verze 0105 · 1996-10-08

Platí pro: MODEL 202.01 /02 /12 up to 30.11.94

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 54 Elektrické zařízení, výstroj a přístroje › 54.15 Pojistková a reléová skříňka — Řada 202 (modely 01*, 02*, 12*)

EinPAS 25 Palubní síť/síť/multifunkční systém › 25.20 Elektrická síť vozidla › 25.20.11 Řídicí jednotka/modul/relé — Řada 202 (modely 01*, 02*, 12*)

EinPAS 25 Palubní síť/síť/multifunkční systém › 25.20 Elektrická síť vozidla › 25.20.40 Elektrická pojistka/dioda/odpor — Řada 202 (modely 01*, 02*, 12*)

AR54.15-P-1255EA

Removing and installing fuse and relay box

12.7.94

MODEL 202.01 /02 /12 up to 30.11.94

Removing and installing fuse and relay box

P54.15-0344-06

Fuse and relay box
Sedans up to 30.11.94

1 Fuse box cover
2 Screws
3 Relay box cover
4 Screw
6 Relay holder
7 Nuts
F1 Fuse and relay box
F1/1 Fuse box (12-fuse, in fuse and relay box F1)

F2 Maxi-fuse box (5-fuse, in fuse and relay box F1)

F3 Fuse box (18-fuse, in fuse and relay box F1)

Removal, installation

1

Disconnect ground cable at the battery

AR54.10-P-0003A

2

Remove cover of fuse box (1)

Examine gasket for signs of damage

3

Remove screws (2)

4

Remove cover of relay box (3)

Check gasket for damage

5

Unscrew screw (4)

6

Remove fuse boxes (F1/1, F2 and F3) and disconnect

7

Disconnect leads on fuse boxes or fuse blocks

Disconnect leads only when changing entire fuse and relay box. To avoid mix-ups bind disconnected leads for individual fuse boxes or blocks together and mark.

AR54.15-P-1255-01EA

Connect leads to fuse boxes or fuse blocks

AR54.15-P-1255-02EA

Fuse block assignment and lead connections

GF54.15-P-1255EB

8

Disconnect all relays

Relay holder assignment

AR54.15-P-1255-03EA

9

Remove exterior lamps failure monitoring unit

Press catch strap

10

Remove relay holder

11

Unclip connectors on bottom of relay holder or carrier

12

Remove connectors for exterior lamp failure monitoring module

AR54.15-P-1255-04EA

Install connectors for exterior lamp failure monitoring module

AR54.15-P-1255-05EA

13

Unscrew nuts (7)

14

Remove fuse and relay box (F1)

Check gasket for damage

15

Reinstall in opposite order

Odkazované dokumenty