W14.40-1472-08
1 | Holes | 4 | Screwdriver | 7 | Magnetic adapter | ||
2 | Fastening hook | 5 | Assembly aid | ||||
3 | Cover | 6 | AdBlue® tank |
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Notes on use, material properties and handling of AdBlue® | |||
| Remove | ||
1 | Unscrew cap (3) of the AdBlue® container (6). | ||
2 | Insert assembly aid (5) into the bores (1). | ||
| Assembly aid for removal/installation of magnetic adapter at AdBlue(R) tank filler neck | ||
3 | With two screwdrivers (4), press the fastening hooks (2) inward in the direction of the arrow and displace assembly aid (5) up to the end stop. | ||
4 | Pull out magnetic adapter (7). | ||
| Install | ||
5 | Press together the fastening hooks (2) by hand and insert assembly aid (5) up to end stop into the bores (1). | ||
| Assembly aid for removing/installing the magnet adapters on the filler neck of the AdBlue® container | ||
6 | Insert magnetic adapter (7) up to end stop into the filler neck of the AdBlue® container (6). | ||
7 | Hold magnetic adapter (7) and pull out assembly aid (5). | When pulling out the assembly aid (5), the fastening hooks (2) engage audibly. | |
8 | Screw on cap (3) of the AdBlue® container (6). |
Odkazované dokumenty
- ah1440n000101a Upozornění k použití, vlastnostem a manipulaci s AdBlue
- as1440z000101a Nebezpečí popálení a opaření při práci na potrubích AdBlue a s nimi spojených součástech.Nebezpečí poranění kůže a očí při zacházení s AdBlue. Nebezpečí otravy při požití AdBlue
- wf5850w144001a