1 | Metering device | 3 | Electrical connector | |
2 | O-ring | 4 | SCR compressed air pressure sensor |
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Note on calculation of tightening torque when using insertion or socket tools with various effective lengths | |||
Notes on use, material properties and handling of AdBlue® | |||
| Remove/install | ||
1 | Switch off ignition. | ||
2 | Disconnect electrical connector (3) at SCR air pressure sensor (4). | ||
3 | Remove SCR air pressure sensor (4) with O-ring (2) at metering device (1). | SCR compressed-air pressure sensor to metering device | |
4 | Install in the reverse order |
Odkazované dokumenty
- ah0000p001501cw Pokyny pro výpočet utahovacího momentu při použití zasouvacích nebo násuvných nástrojů s různými činnými délkami
- ah1440n000101a Upozornění k použití, vlastnostem a manipulaci s AdBlue
- as0000z000201a Nebezpečí poranění kůže nebo očí při zacházení s horkými nebo žhavými předměty
- as1440z000101a Nebezpečí popálení a opaření při práci na potrubích AdBlue a s nimi spojených součástech.Nebezpečí poranění kůže a očí při zacházení s AdBlue. Nebezpečí otravy při požití AdBlue