B49.20-A000-09
1 | Pump module | 4 | Screw plug | 7 | Tool (It lies with the spare part) | ||
2 | Support | 5 | Hole | 8 | Electric connection | ||
3 | Piping | 6 | Pressure regulating valve |
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
Notes on use, material properties and handling of AdBlue® | |||
| Remove | ||
1 | Remove the piping (3) from the pump module (1) | ||
2 | Remove the electric connection (8) | ||
3 | Remove the pump module (1) from the support (2) | ||
4 | Remove the threaded plug (4) | When removing the threaded plug (4), a little amount of AdBlue® can flow out. | |
5 | Screw the threaded end of the tool (7) in the pressure limiting valve (6), extracting it in this way | When removing the pressure limiting valve (6), little amount of fluid can flow out. | |
| Install | ||
6 | Insert the new pressure limiting valve (6) with the thick side of the tool (7) | | |
7 | Screw the new threaded plug (4) | Closing screw in the pump module | |
8 | Install the pump module (1) in the support (2) | Pump module in the bracket | |
9 | Install the electric connection (8) | ||
10 | Fix the piping (3) of the module pump (1) on the support (2) with new cable flexible ties |
Odkazované dokumenty
- ah0000n500001h Upozornění k zamezení poškozením kvůli znečistění a výskytu cizích těles
- ah1440n000101a Upozornění k použití, vlastnostem a manipulaci s AdBlue
- as1440z000101a Nebezpečí popálení a opaření při práci na potrubích AdBlue a s nimi spojených součástech.Nebezpečí poranění kůže a očí při zacházení s AdBlue. Nebezpečí otravy při požití AdBlue