17A03 | Exhaust gas after-treatment control unit ACM |
1 | Bolt |
3 | Spacer |
4 | Console of the bracket on rear right part of the roof |
5 | Connection of the electric plug |
B14.40-0221-06
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Replace the exhaust gas after-treatment control unit | |||
1 | Connect the diagnosis system, start the Xentry and perform the quick test. | Link exhaust gas aftertreatment (ACM) control unit and exhaust gas aftertreatment unit via VeDoc center | |
2 | Select ("Replace control unit") and follow the instructions | The replacement of the unit control is directed by the steps below: | |
3 | The replacement of the exhaust gas after-treatment control unit ACM (17A03) must be documented on VeDoc system | Update VeDoc documentation for exchange of exhaust aftertreatment unit and/or of exhaust aftertreatment control unit (ACM) | |
| Disassemble/assemble | ||
4 | Disconnect the electric connections of the plug (5) of the exhaust gas after-treatment control unit ACM (17A03). | ||
5 | Unscrew the bolts (1) and remove the exhaust gas after-treatment control unit ACM (17A03) with the respective spacers (3). | ||
6 | Check if the spacers (3) are damaged and replace them if needed. | | |
7 | Install and fasten the exhaust gas after-treatment control unit ACM (17A03) with the spacers (3) and the bolts (1). | Exhaust gas after-treatment control unit | |
8 | Place the connection by the electric plug (5) and fasten the wiring with clamps. | ||
9 | Assemble in reverse order |