ar4725d0019a

Empty lines to solenoid valve for liquid phase

Typ ar · téma 47.25 · verze 0101 · 2016-12-16

Platí pro: Engine 111.984 in model 902, 903, 904 with code MY9 (Liquefied Gas Technology (LGT))

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 47 Palivová soustava, přívod energie hnacího řetězce › 47.25 Vedení, hadice — Řada 902 · Řada 903 · Řada 904

EinPAS 16 Zásobování motoru palivem/energií › 16.10 Zásobování palivem › 16.10.13 Potrubí/hadice/ventil — Řada 902 · Řada 903 · Řada 904

Platí také pro motory/převodovky: 111 984

AR47.25-D-0019A

Empty lines to solenoid valve for liquid phase

01.12.2016

Engine

111.984 in model 902, 903, 904

with code MY9 (Liquefied Gas Technology (LGT))

Empty lines to solenoid valve for liquid phase

1

Electrical connection

2

Cable tie

D47.25-1118-06

Danger !

Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas.

Remove any sources of ignition.
Protective clothing, safety gloves and safety glasses must always be worn.
Ensure that the work area is adequately ventilated.
When working on vehicles at ambient temperatures over 60 °C, all gas cylinders must be removed.

AS00.00-Z-0018-01A

Danger !

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

Discharge, fill

1

Release and disconnect electrical connection (1)

2

Set selection switch to gas

After switchover the green diode lights up.

3

Start the engine and allow it to run with the vehicle stationary until the engine stops on its own

Gas system is adequately emptied after engine OFF.

4

Fill in reverse order

Odkazované dokumenty