ar4620t1620ba

Check valve reset

Typ ar · téma 46.20 · verze 0100 · 2006-07-26

Platí pro: Steering 766.376 in MODEL NMB613.358 /388

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 46 Řízení › 46.20 Převodka řízení — Řada 613 (modely 358, 388)

EinPAS 22 Řízení › 22.15 Servořízení › 22.15.13 Potrubí/hadice/ventil — Řada 613 (modely 358, 388)

Platí také pro motory/převodovky: 766 376

AR46.20-T-1620BA

Check valve reset

28.6.04

Steering 766.376 in MODEL NMB613.358 /388

Check valve reset

T46.00-0031-11

1 Front flap

2 Protective cap

3 Test connection

Check valve reset

T46.40-0045-01

Danger!

Risk of injury. Moving parts can pinch, crush or, in extreme cases even sever extremities.

No parts of the body or limbs should be within the operating range of the mechanism when moving components.

AS00.00-Z-0009-01A

1

Jack up vehicle

AR00.60-T-1000B

2

Open front flap (1)

See Operating Instructions

Danger!

Danger of injury to eyes from steering oil emerging at high pressure. Danger of poisoning from swallowing steering oil

Unscrew end limit screws maximum 5 turns. Wear safety glasses.

AS46.00-Z-0001-01A

3

Detach protective cap (2)

4

Connect tester to test connection (3)

AR46.20-T-3055BA

Danger!

Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury caused by contusions and burns when working in engine during starting procedure

Secure vehicle to prevent it from moving.
Wear closed and snug-fitting work clothes.
Do not grasp hot or rotating parts.

AS00.00-Z-0005-01A

5

Start engine and run at idling speed

6

Read off operating pressure on tester

*124589062100

7

Fit thrust piece on the left steering stop of the front axle

*WE58.40-Z-1018-15A

8

Turn the steering wheel counterclockwise

Turn the steering wheel against the left steering stop until a pressure of 10 bar over the operating pressure appears on the tester.

*124589062100

9

Release the steering wheel and observe the display on the tester

The pressure must drop to the operating pressure within a second. The pressure read off on the tester must be a maximum of 0.5 bar over the operating pressure determined in step 6.

*124589062100

10

Repeat work steps 7 to 9 for the clockwise steering angle

11

Turn off engine

12

Detach tester from test connection (3)

AR46.20-T-3055BA

*124589062100

13

Fit on protective cap (2)

14

Close front flap (1)

See Operating Instructions

Check valve reset

Tester

124 589 06 21 00

Workshop equipment

WE58.40-Z-1018-15A

Thrust piece for axle stop, order number766 589 00 63 00

Odkazované dokumenty