ar4260i0020b

Checking and adjusting pressure regulator cutoff pressure

Typ ar · téma 42.60 · verze 0101 · 2007-05-03

Platí pro: MODEL 684.482

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 42 Brzdy - hydraulická část a mechanická část › 42.60 Vzduchotlaková část — Řada 684 (modely 482)

EinPAS 21 Brzdy/podtlakový systém/vzduchotlaké zařízení › 21.15 Provozní brzda/podtlakový systém › 21.15.31 Modulátor/regulátor brzdné síly — Řada 684 (modely 482)

AR42.60-I-0020B

Checking and adjusting pressure regulator cutoff pressure

24.4.07

MODEL 684.482

Checking and adjusting pressure regulator cutoff pressure

I42.60-0108-06

1 Air drier

2 Compressed-air line

3 Sealing ring

4 Banjo bolt

5 Connector

6 Pressure gage

7 Adjustment screw

Checking

Danger!

Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury caused by contusions and burns during starting procedure or when working near the engine as it is running

Secure vehicle to prevent it from moving by itself.
Wear closed and snug-fitting work clothes.
Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

1

Secure vehicle against rolling

2

Depressurize air brake system

Pull vent valve on compressed-air reservoir.

3

Remove compressed air line (2) from air drier (1)

4

Fit connector (5) with seal ring (3) and pressure gauge (6) onto air drier (1)

*360589002100

5

Start engine to fill the air brake system and allow it to run

6

Read off shutoff pressure on the pressure gauge (6)

If the pressure regulator shuts off the air brake system filling process.

*BE42.10-N-1008-10G

7

Turn off engine

Adjust

8

Set shutoff pressure using adjustment screw (7)

Perform only if the shutoff pressure value does not correspond with the specified value.

*BE42.10-N-1008-10G

9

Engage the parking brake several times in succession

To enable the pressure of the air brake system to drop below the set value again.

10

Start engine and let it run until the pressure regulator shuts off, and while doing so read off the new shutoff pressure settings on the pressure gauge (6)

If necessary, the setting should be repeated until the shutoff pressure is OK.

*BE42.10-N-1008-10G

11

Remove the pressure gauge (6) and connector (5) with seal ring (3) on the air drier (1)

12

Install compressed air line (2) onto air drier (1)

Replace sealing rings (3).

Test values for service brake

Number

Designation

Model 684.482

BE42.10-N-1008-10G

Pressure governor cutoff pressure

bar

8.1 (0.2)

Checking and adjusting pressure regulator cutoff pressure

Test kit

360 589 00 21 00

Odkazované dokumenty