AR42.60-B-0070TB | Fill compressed-air reservoir with air from external source | 12.02.16 |
Vehicle 958.0, 958.1
W42.60-0044-01
W42.60-0043-01
1 Closing plug
2 Filling hose
3 Filling connection
6.12 Single chamber air desiccator with integrated pressure regulator
1 | Remove the closing plug (1) and install the filling connection (3) | The filling connection (3) remains installed. | |
2 | Connect the filling hose (2) to the connection (3) | ||
3 | Connect the filling connection (2) to the outside air source and charge the compressed air reservoir | Only carry out the charging from outside source by the connection 12. In vehicles with Code (B56 - with front end terminal for air filling) by the coupling terminal. The reservoirs can be charged up the pressure regulator cut-out pressure. |