ar4260b0040a

Checking service pressures on four-circuit protection valve

Typ ar · téma 42.60 · verze 0200 · 2016-02-12

Platí pro: Vehicle 382.070, 382.071, 382.073, 382.074, 382.083, 382.084, 382.085, 382.087Vehicle 693.### #B, 693.### #D, 694.### #B, 694.### #D, 695.### #B, 695.### #D, 696.### #B, 696.### #D

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 42 Brzdy - hydraulická část a mechanická část › 42.60 Vzduchotlaková část — Řada 382 (modely 070, 073, 074, 083, 084, 085, 087) · Řada 693 · Řada 694 · Řada 695 · Řada 696

EinPAS 21 Brzdy/podtlakový systém/vzduchotlaké zařízení › 21.35 Vzduchotlaké zařízení › 21.35.13 Potrubí/hadice/ventil — Řada 382 (modely 070, 073, 074, 083, 084, 085, 087) · Řada 693 · Řada 694 · Řada 695 · Řada 696

AR42.60-B-0040A

Checking service pressures on four-circuit protection valve

12.02.16

Vehicle 382.070, 382.071, 382.073, 382.074, 382.083, 382.084, 382.085, 382.087

Vehicle 693.### #B, 693.### #D, 694.### #B, 694.### #D, 695.### #B, 695.### #D, 696.### #B, 696.### #D

Checking service pressures on four-circuit protection valve
Checking service pressures on four-circuit protection valve
Checking service pressures on four-circuit protection valve

B42.60-0014-01

B42.60-0015-01

B42.60-0016-01

1 Working pressure setting screw circuits 21 and 22.

2 Manometer connection points for checking circuits 21 and 22.

3 Connection points of the manometer on the pressure regulator test socket.

4 Setting screw of circuits 23 and 24

4.03 4-circuit protection valve.

35.02 Connection point of the manometer installed on the red coupling nozzle (emergency).

35.03 Connection point of the manometer installed on the yellow coupling nozzle (service).

Check

The pressures of the 4-circuit valve (4.03) of the air processing unit should not be adjusted with the valve mounted to the vehicle. This is possible only on a test bench, as per manufacturer's instructions.

1

Installing the test set manometers

Test set

Install the set manometers: On red "Emergency" coupling nozzle (35.02), on pressure regulator test socket (3) and on circuits 21 and 22 (2) of the 4-circuit valve.

2

Pressurize the brake system until the pressure regulator disconnects

Opening pressure of circuits 21 and 22.

*BE42.60-B-1002-01A

Opening pressure of circuits 23 and 24.

*BE42.60-B-1002-01A

Test set

3

Check the opening pressure of circuits 21 and 22

If the pressure varies from indicated value, adjust it.

*BE42.60-B-1002-01A

AR42.60-B-0040-01A

Test set

4

Check the opening pressure of circuits 23 and 24

If the pressure varies from indicated value, adjust it.

*BE42.60-B-1002-01A

AR42.60-B-0040-02A

Test set

Compressed air brake system

Número

Denominação

chassis 368.00/05/10/11/15; 382.07/08/12/15/17/18; 384.06/07/11/14/20/22/31/33; 634.001/011/061; 693.02/10/12/14/15/17/18/19/34/38; 694.00/02/04; 695.01/02/03/04/05; 695.30; 696.08/09; 696.36

BE42.60-B-1002-01A

Protective valve

Opening pressure - Wabco/Knorr - circuits 21 and 22

bar

8,7 ... 9,0

Opening pressure - Wabco/Knorr - circuits 23, 24, 25 and 26

bar

7,2 ... 7,5

Limiting valve opening pressure - Wabco - circuits 23, 24, 25 and 26

bar

8,1 ... 8,5

Closing pressure - Knorr - Circuits 21 and 22

bar

6,3

Closing pressure - Knorr - Circuits 23, 24, 25 and 26

bar

4,5

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Wabco/Knorr - Circuits 21 and 22

bar

7,0

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Wabco - Circuits 23, 24, 25 and 26)

bar

4,5

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Knorr - Circuits 23, 24, 25 and 26

bar

5,5

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Knorr - Circuits 23 and 24

bar (bigger or equal)

-

Pressure limit - Wabco/Knorr - Circuits 23, 24, 25 and 26

bar

8,1 ... 8,5

Safety valve opening pressure - Knorr - Circuits 23, 24, 25 and 26

bar (bigger than)

8,2

Safety valve opening pressure - Knorr - Circuits 23, 24

bar (bigger or equal)

-

Pressure reduction (shifting pressure) - Knorr - Circuits 21 and 22

bar

10,4 ... 10,6

Pressure reduction (shifting pressure) - Knorr - Circuits 23 and 24

bar

8,4 ... 8,6

Pressure reduction (shifting range) - Knorr - Circuits 21, 22, 23 and 24

bar (bigger or equal)

0,5

Admissible leakage - Wabco

bar (smaller or equal to cm3/min)

10,0

Admissible leakage - Knorr

bar

8,0

Bench feeding circuit pressure - Wabco

bar

15,0

Bench feeding circuit pressure - Knorr

bar

11,8 ... 12,2

Pressure during the tightness test - Wabco

bar

10,0

Dynamic safety pressure - Knorr - Circuits 21, 22, 23 and 24

bar (bigger or equal)

-

Odkazované dokumenty