ar4210p001002d

Carrying out bleeding operation

Typ ar · téma 42.10 · verze 0203 · 2007-06-13

Platí pro: MODEL 202 up to 31.5.94 with CODE (471) Acceleration slip regulation (ASR)

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 42 Brzdy - hydraulická část a mechanická část › 42.10 Provozní brzda — Řada 202

EinPAS 21 Brzdy/podtlakový systém/vzduchotlaké zařízení › 21.15 Provozní brzda/podtlakový systém › 21.15.5 Kompletní brzdová soustava — Řada 202

AR42.10-P-0010-02D

Carrying out bleeding operation

Danger!

Risk of poisoning caused by swallowing brake fluid. Risk of injury caused by brake fluid coming into contact with skin and eyes.

Only pour brake fluid into suitable and appropriately marked containers. Wear protective clothing and eye protection when handling brake fluid.

AS42.50-Z-0001-01A

Front axle brake caliper

Number

Designation

Model
202.018/020/
022/023/033/
078/080/081/
083/087/093/
120/121/122/
125/133/134/
180/182/193/
194,
model
202.028
up to 08/95

Model
202.024/025/
026/029/082/
085/086/088/
089/128/188,
model
202.028
as of 09/95

BA42.10-P-1002-10K

Bleed screw to brake caliper

Nm

7

7

Rear axle brake caliper

Number

Designation

Model
202

BA42.10-P-1002-12K

Bleed screw to brake caliper

Nm

7

Carrying out bleeding operation

140 589 03 09 00

Socket wrench

Carrying out bleeding operation

P42.10-0262-06

1 Open bleed screw on brake caliper (1), allow approx. 80 cm3 of brake fluid to flow out free of bubbles, bleeding pressure 2 bar.

2 Repeat the bleeding process at brake calipers 2, 3, 4,, at each brake caliper allow approx. 80 cm3 of brake fluid to flow out free of bubbles.

3 Close bleed screw on brake caliper (1).

Carrying out bleeding operation

P42.40-0239-06

Bleed the feed line and return line of the ASR unit using the handheld tester (HHT)

This operation must only be carried out if the reservoir has run empty or work has been carried out on the master brake cylinder, on the precharging pump, on the hydraulic unit and on the connecting lines.

4 Connect handheld tester (087) with test cable (Multiplexer) (094) to the diagnostic data link connector (X11/4).

5 Start bleeding routine (observe instructions in the display).

At the end of the bleeding process the brake fluid must flow through the return line (10b) into the reservoir without any foam and free of bubbles.

Repeat the bleeding process after a 2 min waiting time in the event of bubbles or foam. If necessary, check and retighten hydraulic connections.

6 Read out and erase fault memory.

7 Switch off ignition.

The system is only operational again after this process.

Odkazované dokumenty