01 | Filling and bleeding device |
1 | First bleed point, right rear |
2 | Second bleed point, left front |
3 | Third bleed point, left rear |
4 | Fourth bleed point, right front |
5 | Diagnostic system |
D42.10-1180-05
1 | Connect filler/bleeder unit (01) to hydraulic fluid reservoir and open shutoff valve. |
D42.10-0018-01
2 | Connect diagnostic system in driver footwell to diagnostic link (6). |
3 | Select program for bleeding brakes. |
D42.10-1172-01
4 | Plug breather hose onto bleed valve designated by diagnostic system and open bleed valve. |
5 | Activate bleeding routine by pressing the Start button. |
D42.10-0017-01
6 | With the bleed valve opened, press brake pedal sharply every 2 to 3 s and allow to move back slowly. |
The bleeding operation is completed once clear brake fluid free of bubbles flows out of the bleeder hose. |
7 | Close the vent valve . |
8 | Continue bleeding operation at the following bleeding points in the same way. |
9 | Disconnect diagnostic system. |
10 | Close shutoff valve and disconnect filler/bleeder unit from hydraulic fluid reservoir. |
11 | Correct fluid level in hydraulic fluid reservoir. |
Fill in quantity of brake fluid required, use brake fluid in accordance with Specifications for Operating Fluids Sheet 331.0. |
D42.10-0016-01