W42.10-1206-05
condensed water sensor (B76) without drain valve
1 Connector
2 Bush
3 O-Ring
B76 condensed water sensor
W42.10-1207-05
Condensed water sensor (B76) with drain valve
1 Connector
2 Bush
3 O-Ring
4 Sensor (drain valve)
5 Protective cover
B76 Condensed water sensor
| Remove | ||
1 | Depressurize the compressed air system | ||
2 | Remove the protective cover | Only in the condensed water sensor (B76) with drain valve, if present. | |
3 | Separate the connector (1) from the socket weld coupling (2) | ||
4 | Remove the condensed water sensor (B76) | ||
| Check | ||
5 | Test the condensed water sensor (B76) with multimeter | Only in case of complaint. | |
Condensed water sensor (B76) without drain valve | |||
Condensed water sensor (B76) with drain valve | |||
Condensed water sensor condition: "dry" | |||
Condensed water sensor condition: "wet" | |||
| Adapter for testing | ||
| Install | ||
6 | Install the condensed water sensor (B76) | A condensed water sensor (B76) that fell must be replaced, even when apparently no damage occurred. | |
Check the O-Ring (3) and replace it, if necessary. | |||
| |||
7 | Link the connector (1) to the socket weld coupling (2) | ||
8 | Install the protective cover | Only in the condensed water sensor (B76) with drain valve, if present. | |
9 | Perform the memory readings of the failures in the maintenance system (WS) and, if necessary, erase the stored failures | ||
10 | Reset the maintenance system (WS) with the STAR DIAGNOSIS or through the tool (INS). | Only when there was no water in the compressed air system and the condensed water sensor (B76) did not provide correctly the corresponding conditions, being, therefore, replaced. |
Service brakes
Número | Denominação | Chassis 958.0; 958.2; 958.4 | |||
BE42.10-B-1017-10E | Sensor of water condensate: "dry" | Volt | 1,1...2 | ||
BE42.10-B-1018-10E | Sensor of water condensate: "wet" | Volt | 3,1...4 | ||
Condensation sensor