ar3222p8100i

Inspecting AIRmatic for leaks

Typ ar · téma 32.22 · verze 0100 · 2004-10-20

Platí pro: MODEL 220 except CODE (487a) Active body control (ABC)

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 32 Odpružení › 32.22 Vzduchové odpružení — Řada 220

EinPAS 20 Podvozek › 20.16 Odpružení › 20.16.1 Základní informace — Řada 220

AR32.22-P-8100I

Inspecting AIRmatic for leaks

21.4.99

MODEL 220 except CODE (487a) Active body control (ABC)

Inspecting AIRmatic for leaks

P32.22-2080-09

Pressure line connections:

1 to AIRmatic compressor unit

1VL to left front spring strut

2VL to right front spring strut

3HL to left rear spring strut

40 Front spring strut

41 Rear spring strut

42 Central reservoir

A9/1 AIRmatic compressor unit

Y36/6 Level control valve unit

4HR to right rear spring strut

5SP to central reservoir

P to AIRmatic compressor unit

40a on front spring strut

41a on rear spring strut

42a on central reservoir

Checking

Notes on AIRmatic

AH32.22-P-1000-02I

1

Remove engine compartment lining

Only on the right-hand side of the vehicle for testing the AIRmatic compressor unit (A9/1)

AR61.20-P-1105M

2

Remove part of the wheel house inner panel in front fender

Only on the right-hand side of the vehicle for testing the level control valve unit (Y36/6)

3

Spray the pressure line connections (1VL, 2VR, 3HL, 4HR, 5SP,P) of the level control valve unit (Y36/6), the pressure line connection of the AIRmatic compressor unit (A9/1) and the pressure line connection (42a) of the central reservoir (42) with leak detecting spray

Wait for approx. 10-15 minutes after spraying. This means that minor leaks can be recognized (forming a white cap). Severe leaks are evident immediately.

Use leak detecting spray

4

Spray the area of the casting compound and pressure line connections (40a, 41a) on the spring struts (40, 41) with leak detecting spray

Wait for approx. 10-15 minutes after spraying. This means that minor leaks can be recognized (forming a foam crown). Severe leaks are evident immediately.

4

Use leak detecting spray

Odkazované dokumenty