Test values for transfer case gear set, shafts
Number | Designation | Model 460, 461 | |
BE28.50-P-1009-01A | Play between shift rod and system | mm | 0.2 |
Transfer case housing
Number | Designation | Model 460, 461 | ||
BA28.40-P-1009-01A | Bolt, shift fork bearing bracket to housing | Nm | 25 | |
Transfer case shift
P28.60-2054-01
1 Put on spacer sleeves, install shift guide and tighten bolts.
P28.60-2055-01
2 Move shift rod into center position and press to one side so that the lug on the bearing bracket abuts the notch of the shift tower.
P28.60-2056-01
3 In this position check the gap between the shift finger and stop plate, adjust if necessary.
The shift finger must be parallel to the stop plate.
P28.60-2057-01
4 Install shift tower (arrow) and tighten bolts.
P28.60-2058-01
5 Install boot and shift lever knob (arrow).