1 | Screw |
2 | Electrical connector |
3 | Compressed-air inlet |
G26.10-A007-06
Caution | Risk of injury to skin and eyes due to handling of transmission oil. Health risk caused by swallowing transmission oil | Wear protective gloves, protective clothing and safety glasses. | |
Topical note | Notes on self-locking nuts and bolts | ||
Note on calculation of tightening torque when using insertion or socket tools with various effective lengths | |||
Notes on compressed air connection systems | |||
Remove/install | |||
1 | Discharge compressed-air system. | See information from body manufacturer. | |
2 | Detach propeller shaft from output flange and place to one side. | See information from body manufacturer. | |
3 | Disconnect electrical connector (2) from transmission control unit (TCM). | ||
4 | Detach compressed-air line from compressed-air inlet (3) of transmission positioner. | When detaching the compressed-air line, make sure that the filter screen does not get lost. | |
Retaining screw, compressed-air line to transmission | |||
5 | Disconnect transmission oil lines from transmission and seal using suitable plugs. | ||
6 | Detach transmission wiring harness, compressed-air line and transmission oil lines from brackets on transmission. | ||
7 | Remove screws (1) and detach transmission from engine. | See information from body manufacturer. Select procedure according to design and accessibility. |