ar2520g0070e

Bleed clutch operating system

Typ ar · téma 25.20 · verze 0101 · 2011-08-23

Platí pro: MODEL 405.05

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 25 Spojka › 25.20 Ovládání spojky — Řada 405 (modely 05*)

EinPAS 17 Hnací ústrojí/náprava › 17.15 Spojka › 17.15.5 Ovládání spojky — Řada 405 (modely 05*)

AR25.20-G-0070E

Bleed clutch operating system

17.8.11

MODEL 405.05

Bleed clutch operating system
Bleed clutch operating system

G25.20-3167-01

1 Cover

2 Expansion reservoir

G25.20-3168-01

Bleed clutch operating system

G25.20-3183-01

3 Bleed valve

Replace

Danger!

Risk of poisoning caused by swallowing brake fluid. Risk of injury caused by brake fluid coming into contact with skin and eyes.

Only pour brake fluid into suitable and appropriately marked containers. Wear protective clothing and eye protection when handling brake fluid.

AS42.50-Z-0001-01A

1

Check accessible components in clutch operating system for external leaks

Replace components if they are damaged.

The clutch operating system is a very sensitive electrohydraulic system. Even the smallest amount of air in the hydraulic section will cause irreparable damage in this system.

Bleeding must be performed extremely carefully in order to ensure that the system functions correctly following the bleeding procedure. Any air pockets in the system can prevent the electronics from engaging a gear thus disabling the vehicle.

2

Replacing brake fluid of clutch operating system

Only if the brake fluid has not been changed within the last three years.

AP25.20-G-2981E

3

Remove cover (1)

4

Open cap of expansion reservoir (2) and extract old brake fluid

The level of the brake fluid should still extend to above that of the supply opening.

Brake fluid notes

AH42.50-P-0001-01A

5

Connect filling and bleeding device to expansion reservoir (2)

To ensure that bleeding is performed properly, only the approved filler/bleeder units should be used.

Pay attention to manufacturer's operating instructions. The filler/bleeder unit must be completely full.

Brake fluid as per Specifications for Operating Fluids:

Brake fluids (DOT 4 plus)

Sheet 331.0

BB00.40-P-0331-00A

6

Switch on filler/bleeder unit

Set the bleeding pressure to a max.
2.7 bar. The bleeding pressure must not drop below 1.5 bar. The filler/bleeder unit remains switched on during the entire bleeding procedure.

7

Replace brake fluid

Drawn-off brake fluid must not be reused.

Bleed at the bleed valve (3) of the slave cylinder until fresh brake fluid emerges free of bubbles.

Assist the bleeding procedure by depressing the clutch pedal once, from fully open to fully closed (on vehicles with overcenter spring there is a risk of crushing injuries).

8

Switch off and disconnect filler/bleeder unit

Pay attention to manufacturer's operating instructions.

9

Check fluid level in expansion reservoir (2); correct if necessary

AP25.20-G-2910B

10

Check clutch operating system

The compressed-air system must be filled up to the cutoff pressure.

AP25.20-G-2957E

11

Install paneling (1)

Odkazované dokumenty