ar2040b5616a

Remove/install electromagnetic fan clutch

Typ ar · téma 20.40 · verze 0201 · 2020-02-20

Platí pro: Engine 457.9 in model 382.15, 634.011/061/071/081 Engine 906.9 in model 382.175/184/186 Engine 926.9 in model 382.171/176, 634.001

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 20 Chlazení motoru › 20.40 Větrák chladiče, spojka větráku chladiče — Řada 382 (modely 15*, 171, 175, 176, 184, 186) · Řada 634 (modely 001, 011, 061, 071, 081) · Řada 906 (modely 9**)

EinPAS 15 Motor › 15.25 Chladicí systém motoru › 15.25.45 Ventilátor/spojka ventilátoru/pohon větráku — Řada 382 (modely 15*, 171, 175, 176, 184, 186) · Řada 634 (modely 001, 011, 061, 071, 081) · Řada 906 (modely 9**)

Platí také pro motory/převodovky: 457 9**, 926 9**

AR20.40-B-5616A

Remove/install electromagnetic fan clutch

03.02.2020

Engine

457.9 in model 382.15, 634.011/061/071/081

Engine

906.9 in model 382.175/184/186

Engine

926.9 in model 382.171/176, 634.001

Remove/install electromagnetic fan clutch

Fan with electromagnetic coupling system - Linnig

1

Actuation connector

2

Fan

3

Nut

4

Electromagnetic clutch

5

Holder

6

Bolt

7

Fan pulley

B20.40-0015-06

Remove/install

1

Open the access cover to the engine compartment

Accumulation of dirt, chiefly on the coupling front face where the bimetallic blade is located, may cause inadequate fan operation. If necessary, clean with water, paying attention not to damage the two metal blade.

The access for carrying out the works and repairs vary according to the body type/manufacturer.

Refer to the body makers instructions.

2

Remove the radiators

3

Unplug the drive connector (1)

4

Unscrew the bolts (6) and remove the drive pulley (7)

Check the drive belt for condition. Replace if necessary.

5

Remove the nuts (3) from the electromagnetic clutch (4) to the bracket (5)

6

Remove the fan (2) from the electromagnetic clutch (4)

In the case of electromagnetic coupling failure, fasten the two bolts for the lock-up. After the maintenance, remove them.

At removal of the electromagnetic coupling, mark the corresponding bolt fitting holes for the repositioning.

7

Installation in reverse order