ar2010t245501b

Test operation and start of opening of coolant thermostat

Typ ar · téma 20.10 · verze 0102 · 2005-07-12

Platí pro: ENGINE 441.980 in MODEL 613.355 /364 /365 ENGINE 402.970, 446.938 in MODEL 613.455 /485

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 20 Chlazení motoru › 20.10 Čerpadlo chladicí kapaliny, termostat chlazení — Řada 441 (modely 980) · Řada 613 (modely 355, 364, 365, 455, 485)

EinPAS 15 Motor › 15.25 Chladicí systém motoru › 15.25.30 Čerpadlo/termostat/předehřívací zařízení — Řada 441 (modely 980) · Řada 613 (modely 355, 364, 365, 455, 485)

Platí také pro motory/převodovky: 402 970, 446 938

AR20.10-T-2455-01B

Test operation and start of opening of coolant thermostat

Test data of coolant thermostat

Number

Designation

Engine 402.970

Engine 441.980

Engine 446.938

BE20.10-N-1001-02E

Coolant thermostat
start of opening

Standard version

°C

83 (2)

83 (2)

83 (2)

Tropical version

°C

71 (2)

71 (2)

71 (2)

BE20.10-N-1002-02E

Coolant thermostat
main valve

Standard version

Fully open

°C

95

95

95

Stroke

mm

8

8

8

Tropical version

Fully open

°C

85

85

85

Stroke

mm

8

8

8

BE20.10-N-1003-02E

Coolant thermostat
bypass valve

Standard version

closed

°C

92

92

92

Stroke

mm

6...7.5

6...7.5

6...7.5

Tropical version

closed

°C

82

82

82

Stroke

mm

6...7.5

6...7.5

6...7.5

BE20.10-N-1004-02E

Leak water quantity of main valve

Standard version

1 kp/cm2 and 20 °C

l/min

0.67...1.17

0.67...1.17

0.67...1.17

Tropical version

1 kp/cm2 and 20 °C

l/min

0.67...1.17

0.67...1.17

0.67...1.17

BE20.10-N-1005-02E

Flow quantity when main valve open

Standard version

1 kp/cm2 and 20 °C

l/min

333

333

333

Tropical version

1 kp/cm2 and 20 °C

l/min

333

333

333

Test start of opening

1 Attach coolant thermostat to a wire and suspend in a vessel filled with water.

2 Use a suitable source of heat to heat the water.

On no account use a welding torch or soldering tool for heating the water.

The heating-up rate should not be more than 1-2 °C per minute from about 8 °C prior to start of opening. Stir the water as it is heating up (uniform heating).

Test operation

1 Attach coolant thermostat to a wire and suspend in a vessel which is filled with boiling water.

The main valve of the coolant thermostat must be fully opened after 6-8 minutes.