P20.10-2017-06
1 Thermostat housing
2 Thermostat
3 Sealing ring
4 Coolant connection
5 Connection
| Remove/install | ||
Danger! | Risk of injury to skin and eyes caused by scalding from contact with hot coolant spray. Risk of poisoning caused by swallowing coolant. | Do not open cooling system unless coolant temperature is below 90°C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. Wear protective gloves, protective clothing and safety glasses. | |
1 | Drain coolant at radiator | ||
2 | Remove coolant connection (4) | ||
3 | Detach coolant hose to expansion reservoir at connector (5) | Inspect condition of coolant hose and hose clamp, replace if necessary. | |
4 | Remove thermostat housing (1) with thermostat (2) | Installation: Replace compression ring (3). | |
| |||
5 | Remove thermostat (2) from thermostat housing (1) | ||
6 | Install in the reverse order | ||
7 | Inspect cooling system for leaks |
Coolant pump, coolant thermostat
Odkazované dokumenty
- ar2000p1010ha Zkontrolovat těsnost chladicího systému
- ar2000p1010ha
- ar2000p1142ha Vypuštění, doplnění chladicí kapaliny
- ar2000p1142ha
- as2000z000101a Nebezpečí poranění kůže a očí opařením vystřikující, horkou chladicí kapalinou. Nebezpečí otravy při požití chladicí kapaliny