ar2010g129002de

Remove/install connection piece of coolant pump to cylinder head

Typ ar · téma 20.10 · verze 0101 · 2011-01-20

Platí pro: ENGINE 900.91 /92, 902.91 /93, 904.94 /95 /96 /97, 906.93 /94 /95 /96 /98 /99, 924.91 /93, 926.91 /92 /93 /95 /97 in MODEL 000.001

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 20 Chlazení motoru › 20.10 Čerpadlo chladicí kapaliny, termostat chlazení — Řada 000 (modely 001) · Řada 900 (modely 91*, 92*) · Řada 902 (modely 91*, 93*) · Řada 904 (modely 94*, 95*, 96*, 97*) · Řada 906 (modely 93*, 94*, 95*, 96*, 98*, 99*)

EinPAS 15 Motor › 15.25 Chladicí systém motoru › 15.25.30 Čerpadlo/termostat/předehřívací zařízení — Řada 000 (modely 001) · Řada 900 (modely 91*, 92*) · Řada 902 (modely 91*, 93*) · Řada 904 (modely 94*, 95*, 96*, 97*) · Řada 906 (modely 93*, 94*, 95*, 96*, 98*, 99*)

Platí také pro motory/převodovky: 924 91*, 924 93*, 926 91*, 926 92*, 926 93*, 926 95*, 926 97*

AR20.10-G-1290-02DE

Remove/install connection piece of coolant pump to cylinder head

Danger!

Risk of injury to skin and eyes caused by scalding from contact with hot coolant spray. Risk of poisoning caused by swallowing coolant.

Do not open cooling system unless coolant temperature is below 90°C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers.

Wear protective gloves, protective clothing and safety glasses.

AS20.00-Z-0001-01A

Coolant pump, coolant thermostat

Number

Designation

Engines
900.9, 902.9, 904.9, 906.9

Engine 924.9, 926.9

BA20.10-N-1003-01L

Bolt, connection piece of coolant pump to cylinder head

Nm

50

50

Remove/install connection piece of coolant pump to cylinder head

W20.10-1042-11

Shown on engine 926.9

1 Disconnect electrical connector (6).

2 Detach coolant hose (4) at connection piece (1).

3 Unscrew connection fitting (2)

Installation: Replace sealing ring.

4 Remove bolts (3) and remove crankcase breather line (5).

Installation: Tighten bolts (3).

5 Pull connecting piece (1) upwards and out of connection fitting.

Installation: Install new seal and connection fitting.

6 Install in the reverse order.