T15.40-0020-08
1 Cooling air intake hose
2 Cooling air intake cover
3 Alternator II
4 Electrical line
5 Tensioning device
| Remove/install | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
1 | Disconnect electric cables at battery. | ||
2 | Open rear flap and service flap at right rear | ||
3 | Detach cooling air intake hose (1) | Check cooling air intake hose (1) for brittleness and damaged points; replace if necessary. | |
4 | Detach cooling air intake cover (2) from alternator II (3) | ||
5 | Detach electric cables (4) from alternator II (3) | | |
| |||
6 | Remove V-belt from alternator II (3) | ||
7 | Detach tensioning device (5) | ||
8 | Remove bolts (arrows) and alternator II (3) from carrier | | |
9 | Install in the reverse order |
Alternator
Odkazované dokumenty
- ar1321t0140ba
- ar5418t0002cb
- as5410z000101a Nebezpečí požáru/exploze kvůli zkratu a unikajícímu výbušnému plynu. Nebezpečí popálení/poranění poleptáním očí, pokožky a sliznic elektrolytem / elektrolytovou mlhou akumulátoru při zkratu nebo následkem světelné