W14.40-1018-08
1 | Pump module | 4 | AdBlue piping (supply) | 7 | Pressure filter housing | ||
2 | Insulating hose | 5 | AdBlue pipe (return) | 8 | Filter Element | ||
3 | Pipe nozzle (AdBlue supply) | 6 | Pipe nozzle (AdBlue return) | 9 | Filter cup |
| Remove/install | ||
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
1 | Release the AdBlue pipes clamps (4,5) | Clamp | |
Notes on use, material properties and handling of AdBlue® | |||
2 | Remove the filter cup (9) with filter element (8) in the pressure filter housing (7) | Installation: Clean the pressure filter housing (7) and replace the filter bowl (9) together with the filter element (8). Before installation, apply a thin layer of MB silicon grease to the sealing ring of the filter element (8) and the filter cup (9). | |
.Filter bowl on the pump module | |||
3 | Install in reverse order | ||
4 | Check the tightness of filter cup (9) | Visual inspection. |
000 589 54 37 00
Clamp
Odkazované dokumenty
- ah1440n000101a Upozornění k použití, vlastnostem a manipulaci s AdBlue
- as1440z000101a Nebezpečí popálení a opaření při práci na potrubích AdBlue a s nimi spojených součástech.Nebezpečí poranění kůže a očí při zacházení s AdBlue. Nebezpečí otravy při požití AdBlue