P09.20-2319-09
2 | Screw/bolt | 5 | Electrical connection | 8 | Screw/bolt | ||
3 | Exhaust gas recirculation line | 6 | Clamp | 9 | Mixing chamber | ||
4 | Screw/bolt | 7 | Screw/bolt |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
| Remove/install | ||
1 | Remove upper engine cover | ||
2 | Detach exhaust gas recirculation cooler, swivel with attached coolant lines upwards and fix in place | ||
3 | Remove screw/bolts (2) and take off EGR line (3) | Installation: Replace seal. | |
Bolt, exhaust gas recirculation line to charge air distributor | |||
Screw/bolt, exhaust gas recirculation line to valve housing | |||
4 | Remove screw/bolts (4) | Bolt, charge air manifold to charge air distribution line | |
5 | Disconnect electrical connection (5) | ||
6 | Detach clamp (6) with engine wiring harness at mixing chamber (9) | Installation: Attach cable bracket (6) at the same position again. | |
7 | Remove screw/bolts (7) and place bracket to one side | If necessary place the vacuum line to one side until the screw/bolts (7) are accessible on the left side of the mixing chamber (9). | |
Bolt, charge air manifold to charge air line | |||
8 | Unscrew screw/bolts (8) and take off mixing chamber (9) | | |
Installation: Replace seals. | |||
9 | Install in the reverse order |