001 589 53 21 00
Dial gage
541 589 00 40 00
Dial indicator holder
1 | Mount the dial indicator (5) on the dial indicator holder (4) |
2 | Position the dial gauge (5) with some previous tension on the flat face of the cylinder head (1). |
On a cylinder head (1) with inductance thermal treatment the dial gauge holder (4) with the dial gauge (5) must be on the flat surfaces between the inductance treatment points. |
3 | Set the dial gauge (5) to "0". |
4 | Displace the dial indicator (5) with the dial indicator holder (4) until the probe pin rests on the intake valve disk (2) or the exhaust valve (3). |
Measure the valve recess (B) on both valves, intake (2) and exhaust valve (3). On each measuring set the dial gauge (5) to "0". |
5 | Read the value on the dial gauge scale (5) and take note. |
The valve recess (B) must be within the permissible tolerance field on the pair of intake valves (2) or on the pair of exhaust valves (3). |
W05.30-1085-06