over a length of 150 mm in longitudinal and transverse direction
mm
0.015
D01.30-0052-01
1 Use knife-edge straightedge (2) to measure flatness of cylinder head contact surface (1) over its entire length and diagonally.
If a light gap is formed
2 Use a feeler gage (0.04 mm) to inspect permissible variation.
It must not be possible to insert the feeler gage (0.04 mm) between crankcase contact surface (1) and knife-edge straightedge (2). If the inspection is carried out in the transverse direction, the permissible variation stated is merely a reference value and cannot be measured.