ar0019p012005a

Remove contacts from E 95 coupling

Typ ar · téma 00.19 · verze 0109 · 2009-06-23

Platí pro: MODEL all

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 0 Celkový › 00 Celkové vozidlo › 00.19 Elektrická soustava vozidla, celkové propojení — Řada 900 (modely 9**) · Řada 902 (modely 9**) · Řada 904 (modely 918, 919, 924, 925, 938, 943, 957) · Řada 906 (modely 917, 918, 924, 953)

EinPAS 25 Palubní síť/síť/multifunkční systém › 25.25 Hlavní kabelový svazek › 25.25.1 Základní informace — Řada 900 (modely 9**) · Řada 902 (modely 9**) · Řada 904 (modely 918, 919, 924, 925, 938, 943, 957) · Řada 906 (modely 917, 918, 924, 953)

Platí také pro motory/převodovky: 139 ***, 254 ***, 256 ***, 272 ***, 276 ***, 282 ***, 457 9**, 541 9**, 542 9**, 608 ***, 700 4**, 700 420, 700 421, 700 422, 700 423, 715 3**, 715 5**, 722 6**, 722 9**, 724 ***, 724 0**, 724 033, 724 044, 724 045, 724 1**, 724 103, 724 114, 724 115, 724 120, 725 ***, 725 0**, 725 035, 725 037, 725 038, 725 085, 725 1**, 739 390, 739 391, 739 395, 739 396, 739 397, 739 398, 739 399, 740 698, 743 3**, 743 4**, 743 498, 746 971, 924 9**, 924 910, 925 9**, 926 9**

AR00.19-P-0120-05A

Remove contacts from E 95 coupling

Remove contacts from E 95 coupling
Remove contacts from E 95 coupling
Remove contacts from E 95 coupling
Remove contacts from E 95 coupling

000 589 13 99 00

Blade holder with clamping pliers

Wiring harness repair kit, basic

New passenger vehicle wiring harness repair kit

E 95 blade

220 589 04 99 00

220 589 01 99 50

220 589 01 99 55

Remove contacts from E 95 coupling

P54.18-2504-01

Unfasten secondary release on version with "E 95 coupling" tab

1 Using a suitable tool, push tab in direction of arrow out of locked position.

Remove contacts from E 95 coupling

P54.18-2505-01

Unfasten secondary release on version with "E 95 coupling" slide

2 Using a suitable tool, move slide in direction of arrow into pre-locking position (1).

Remove contacts from E 95 coupling

P54.18-2506-01

Unfasten secondary release on version with "E 95 coupling" securing clip

3 Push retainer (1) in direction of arrow out of locked position using a suitable tool.

The seal may be damaged if the tool is inserted too.

Remove contacts from E 95 coupling

P54.18-2517-04

Unfasten secondary release on version with "E 95 coupling" contact retainer

4 Press on tabs of contact retainer between the contact cavities
(3, 5 or 4, 6) with suitable tool.

5 Open contact retainer.

Remove contacts from E 95 coupling

P54.18-2503-06

Unpin female contacts from "E 95 coupling"

6 Insert blade holder with clamping pliers and E 95 blade from front side though openings at contact cavity of coupling (2).

Insert tool carefully to prevent damaging webs between contact cavity and openings for release tool.

This pushes together the springs at the female contact (1).

7 A slight tug on the corresponding cable will remove the female contact (1) from the coupling (2).