ar0019p012004a

Remove contacts from micro quadlock system coupling

Typ ar · téma 00.19 · verze 0111 · 2009-06-23

Platí pro: MODEL all Micro-Quadlock-System-Kupplung Variante 1

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 0 Celkový › 00 Celkové vozidlo › 00.19 Elektrická soustava vozidla, celkové propojení — Řada 900 (modely 9**) · Řada 902 (modely 9**) · Řada 904 (modely 918, 919, 924, 925, 938, 943, 957) · Řada 906 (modely 917, 918, 924, 953)

EinPAS 25 Palubní síť/síť/multifunkční systém › 25.25 Hlavní kabelový svazek › 25.25.1 Základní informace — Řada 900 (modely 9**) · Řada 902 (modely 9**) · Řada 904 (modely 918, 919, 924, 925, 938, 943, 957) · Řada 906 (modely 917, 918, 924, 953)

Platí také pro motory/převodovky: 139 ***, 254 ***, 256 ***, 272 ***, 276 ***, 282 ***, 457 9**, 541 9**, 542 9**, 608 ***, 700 4**, 700 420, 700 421, 700 422, 700 423, 715 3**, 715 5**, 722 6**, 722 9**, 724 ***, 724 0**, 724 033, 724 044, 724 045, 724 1**, 724 103, 724 114, 724 115, 724 120, 725 ***, 725 0**, 725 035, 725 037, 725 038, 725 085, 725 1**, 739 390, 739 391, 739 395, 739 396, 739 397, 739 398, 739 399, 740 698, 743 3**, 743 4**, 743 498, 746 971, 924 9**, 924 910, 925 9**, 926 9**

AR00.19-P-0120-04A

Remove contacts from micro quadlock system coupling

Remove contacts from micro quadlock system coupling
Remove contacts from micro quadlock system coupling
Remove contacts from micro quadlock system coupling
Remove contacts from micro quadlock system coupling

000 589 13 99 00

Blade holder with clamping pliers

Wiring harness repair kit, basic

New passenger vehicle wiring harness repair kit

MQS blade

220 589 04 99 00

220 589 01 99 50

220 589 01 99 60

Remove contacts from micro quadlock system coupling

P00.19-2966-01

Unfasten secondary release on version with retaining cap

1 Guide suitable tool (1) all the way into groove (4) from the side.

2 Remove retaining cap (2) from coupling housing (3) in direction of arrow.

Remove contacts from micro quadlock system coupling

P00.19-2958-01

Unfasten secondary release on version with retainer housing (shown on micro quadlock system/Multi Contact Point coupling)

3 Lift locking catch (2) of retaining cap (4) using a suitable tool (1).

4 Pull coupling housing (3) from retaining cap (4) in direction shown by arrow.

Remove contacts from micro quadlock system coupling

P54.18-2224-01

Unfasten secondary release on version with cap

5 Detach cover (1) from cap (2) in direction of arrow over the catch mechanism.

6 Remove connector housing (3) from cap (2) in direction of arrow.

Remove contacts from micro quadlock system coupling

P54.18-2471-01

Unfasten secondary release on version with 2nd contact retainer

7 Using a suitable tool, open the contact retainer (1).

8 Pry up the contact retainer (1) in direction shown by arrow.

Remove contacts from micro quadlock system coupling

P54.18-2472-01

Unfasten secondary release on version with lock tab

9 Push suitable tool underneath locking catches (1).

10 Pry up the lock tabs (1) in direction shown by arrow.

Remove contacts from micro quadlock system coupling

P00.19-3526-01

Unfasten secondary release on version with retainer housing

11 Using a suitable tool, pry up the locking tab on the retaining cap (5).

12 Pull coupling housing (6) from retaining cap (5) in direction of arrow.

Remove contacts from micro quadlock system coupling

P54.18-2222-06

Unpin female contacts from coupling

13 Attach blade holder with clamping pliers and MQS blade from above through opening in exposed connector housing (1) at spring shackle of female contact (2).

14 Press the spring shackle of the female contact (2) downward and push the female contact (2) out of the contact cavity of the connector housing (1). Tug the corresponding cable at the same time to assist the unpinning procedure.

Remove contacts from micro quadlock system coupling

P00.19-3015-06

Unpin female contacts from coupling with
2nd contact retainer

15 Attach blade holder with clamping pliers and MQS blade from above through opening (3) of connector housing (1), press down spring shackle of female contact (2), and pull female contact (2) out of contact cavity of connector housing (1) to end stop.

16 Attach blade holder with clamping pliers and MQS blade from above through opening (4), press down spring shackle of female contact (2), and pull female contact (2) out of contact cavity of connector housing (1).

Tug the corresponding cable at the same time to help unpinning procedure.