AP83.55-T-8311A | Air conditioning - checking oil level in refrigerant compressor | 30.10.98 |
MODEL NMB613.355 /455 /485 except CODE (HA4) Konvekta air conditioning with roof heater and timer
MODEL NMB613.455 except CODE (HKB) Konvekta ACX 641 SAPTCO air conditioning without roof heater
MODEL NMB613.455 except CODE (HKE) Konvekta ACX 642 air conditioning with roof heater
T83.55-0001-01
1 Inspection glass on refrigerant compressor
| Check | ||
Danger! | Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
1 | Check oil level through inspection glass on refrigerant compressor (1) | The oil level is correct when the oil is visible in the inspection glass on the refrigerant compressor (1). If the oil level is not correct: | |
Fill up oil for refrigerant compressor (1) subject to separate repair order. The oil for the refrigerant compressor (1) must comply with the specifications for operating fluids and may only be filled up in workshops that have the necessary expertise and technical equipment. | |||
| Compressor oils | Sheet 362.0 |
Odkazované dokumenty
- as8300z000101a Nebezpečí exploze při svářečských nebo pájecích pracích na uzavřené klimatizaci. Nebezpečí otravy při vdechnutí přehřátých výparů chladiva. Nebezpečí poranění při kontaktu očí a kůže s tekutým chladivem
- bb0040p036200a Kompresorové oleje (specifikace 362.0)