AP83.00-W-8381D | Replace dust filter for heating/air conditioning | 26.7.11 |
MODEL 950.0 /1 /2 /3, 952.0 /1 /2 /3, 953.1 /3, 954.0 /1 /2 with BODY 942.899
N83.00-0338-01
1 Retaining rubber
2 Dust filter
3 Recirculated air filter
N83.00-0339-01
| Removing | ||
1 | Unhook retaining rubber (1). | Check condition of retaining rubber (1), replace if necessary. | |
2 | Remove dust filter (2) | ||
3 | Remove recirculating air filter (3) | ||
| Install | ||
4 | Install new recirculating air filter (3) | Check for correct seating. | |
5 | Install new dust filter (2). | Only replace dust filter with code (HF3) Activated charcoal filter together with activated charcoal filter in air conditioning heater unit, | |
Remove/install activated charcoal filter | |||
6 | Hook in retaining rubber (1) | ||
7 | Confirm filter (2) replacement in maintenance booklet |