P83.10-0211-01
P83.10-0210-01
2 Air box
3 Screws
43, 44 Main air flap element
Arrow Lip seal
P83.10-0209-01
P83.10-0202-01
2 Air box
7 Surface heater thermovalve
10 Water drains
B10/5 Ambient air temperature sensor
| Removing, installing | ||
1 | Pull off lip seal (arrow) | ||
2 | Detach vacuum pipes at the elements of the main air flap (43, 44) | ||
3 | Remove screws (3) | ||
4 | Lift air box (2) | ||
5 | Unclip thermovalve surface heater (7) to the left (arrow) | ||
6 | Pull out ambient air temperature sensor (B10/5) | ||
7 | Take off air box (2) | The water drains (10) should be inserted free of kinks | |
8 | Take out dust filter | The dust filter must not be cleaned but should be replaced On models with activated charcoal filter (CODE 306a) the dust filter is designed as an activated charcoal prefilter and is provided with an activated charcoal layer on the underside. On no account should an only-dust filter be inserted. | |
9 | Install in the reverse order |