AP54.10-P-5452M | Batteries - check state of charge, recharge | 22.6.05 |
MODEL 220.175 /176 /178 with CODE (Z04) Light armoring
Emergency start battery
MODEL 220.175 /176 /178 with CODE (Z07) Top protection
P54.10-2588-06
1 High current relay
2 Emergency start battery
| Remove/install | ||
Danger! | Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury caused by contusions and burns during starting procedure or when working near engine | Secure vehicle to prevent it from moving. | |
1 | Open trunk lid | ||
2 | Remove side paneling in the right of the luggage compartment | Remove side paneling from working area. | |
| Check | ||
3 | Start engine | Allow engine speed to run at idle speed (below 1000 rpm). | |
4 | Measure voltage | Use multimeter to measure voltage at the emergency start battery (2) and note value. | |
The battery must be checked at a battery voltage < 12.2 V, see: | |||
| Checking battery condition | ||
5 | Press the activate button for the emergency start device | The activate button for the emergency start device is located in the glove box on the right side. | |
Enlist the support of a second assistant. The high current relay (1) must switch audibly when the activate button is pressed. | |||
6 | Measure voltage | Use multimeter to measure the voltage again at the emergency start battery (2)The voltage must change positively or negatively depending on the charge level of the emergency start battery (2). | |
The emergency start device is in order if the voltage changes. If no change in voltage occurs, establish and eliminate the cause subject to a separate repair order. | |||
7 | Install in the reverse order |
Odkazované dokumenty
- ar5410p1129i Kontrola stavu akumulátoru
- ar5410p1129i
- as0000z000501a Nebezpečí úrazu při samovolném rozjetí vozidla při běžícím motoru. Nebezpečí poranění pohmožděním a popálením při výkonech prováděných během startování nebo při běžícím motoru