Reservoir and receiver cylinder |
1 | Bleeding device connection |
Bleeding bolt (arrow) |
B29.00-0001-01
B29.00-0002-01
Caution | Risk of poisoning from swallowing brake fluid. Risk of injury from skin and eye contact with brake fluid | Only pour brake fluid into suitable and appropriately marked containers. Wear protective clothing and eye protection when handling brake fluid. | |
1 | Remove the fluid reservoir lid | Observe the operation manual. | |
2 | Connect the bleeding device (1) | Adjust the bleeding device service pressure to 1.5 bar, use the bleeding equipment.. | |
3 | Remove the protection cover and connect a hose in the bleeding bolt (arrow) of the receiver cylinder | This hose is to make the fluid collection that leaves the bleeding bolt to the collection container easier. | |
4 | Loosen the bleed bolt | Duration of the flow of minimum 3 minutes with a flow pressure of 1.5 bar in the bleeding device. The new brake fluid must leave free from bubbles in the bleeding hose. | |
5 | Tighten the bleeding bolt | Remove the hose, check the tightness and reinstall the protection cover. | |
6 | Disconnect the bleeding device (1) | ||
7 | Correct the fluid level in the reservoir | The refueling will be correct when the level is within the maximum (A) and minimum (B) level marks in the reservoir. |
Odkazované dokumenty
- as4250z000101a Nebezpečí otravy při požití brzdové kapaliny. Nebezpečí poranění při kontaktu brzdové kapaliny s kůží a očima