ap0910b0951a

Air filter element - checking fouling. Replace according to condition

Typ ap · téma 09.10 · verze 0300 · 2016-02-12

Platí pro: Vehicle 364.2## #C, 364.2## #D, 364.3## #C, 364.3## #DVehicle 382.0, 382.15, 382.17, 382.18Vehicle 634.001Vehicle 664.0, 664.1, 664.2

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 09 Sání vzduchu, plnění › 09.10 Vzduchový filtr — Řada 364 (modely 2**, 3**) · Řada 382 (modely 0**, 15*, 17*, 18*) · Řada 634 (modely 001) · Řada 664 (modely 0**, 1**, 2**)

EinPAS 15 Motor › 15.30 Sání vzduchu/přeplňování › 15.30.40 Vzduchový filtr/skříň vzduchového filtru — Řada 364 (modely 2**, 3**) · Řada 382 (modely 0**, 15*, 17*, 18*) · Řada 634 (modely 001) · Řada 664 (modely 0**, 1**, 2**)

AP09.10-B-0951A

Air filter element - checking fouling. Replace according to condition

12.02.16

Vehicle 364.2## #C, 364.2## #D, 364.3## #C, 364.3## #D

Vehicle 382.0, 382.15, 382.17, 382.18

Vehicle 634.001

Vehicle 664.0, 664.1, 664.2

Air filter element - checking fouling. Replace according to condition

B09.10-0041-01

Mechanical service indicator

1 Indicator device plunger

2 Releasing knob

3 Sight glass

Air filter element - checking fouling. Replace according to condition

B09.10-0022-01

Electrical service indicator

A Service indicator pilot lamp (air filter element saturation)

Check

Run the engine until water in the cooling system reaches operating temperature

Mechanical service indicator

1.1

Check plunger position (1) on the service indicator sight glass (3)

As filter element saturation occurs, depression increases and the plunger is drawn against its spring action, retained in intermediate positions according to the element degree of saturation.

When the plunger is retained in the maximum saturation position (plunger fully visible in the sight glass of the indicator device body), replace filter element.

For models 382.180/181/185/188/189.

AP09.10-B-0980L

After replacing the filter element, press the release button (2) located at the end of the service indicator device to release the plunger, making it return to low-saturation of the air cleaner.

Electrical service indicator

1.2

Replace the filter element when the pilot lamp of the service indicator illuminates, indicating its saturation or after the maximum limit of two years

For models 382.0, 364, 664.

AP09.10-B-0980K

For models 382.154/155/157/158/175/176/177/184/186, 634.001.

AP09.10-B-0980M

Odkazované dokumenty