S83.70-1026-01
1 Mark and drill the 5 mm hole on the inside of the side wall according to the illustration.
2 With the aid of the 34 mm clamp and the rubber damper, install the fuel metering pump on the side wall.
On the pressure side, the fuel metering pump must be installed with an approx. increase of 20°.
S83.70-1027-01
3 Route the fuel pipe from the metering pump to the heater (4 x 1.25 x 480 mm plastic pipe), connect it with 3.5 x 3 x 50 mm hoses and secure it with 9 mm clamps
4 Secure the fuel pipe in the intake pipe using cable clips.
S83.70-1028-01
5 Disconnect the fuel return pipe and cut a piece measuring approx. 50 mm which corresponds to the T-part.
Identify the fuel return pipe in the fuel filter.
6 Insert two 8 mm bushings in the ends of the fuel return pipe.
7 Insert the 6-8-6 T-part in the fuel return pipe with 7.5 x 2.5 x 50 mm hoses and secure it with 12 mm clamps.
The 6 mm connector of the 8-6-8 T part must point down.
8 With the cable clip secure the fuel return pipe in the fuel supply pipe.
9 Route the fuel pipe from the T-part of the fuel return pipe to the fuel metering pump (plastic tube 6 x 2 x 500 mm), connect with 5 x 3 x 50 mm hoses by means of 11 mm .
10 Secure the fuel pipe with clips.
11 Stick the warning sticker on the inside of the tank cover.