AD83.70-W-6000-46A | AHE test of electrical system combustion air blower |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Combustion air blower EMK Flame monitor | X6 a X6 b |
|
| Ignition: OFF Remove heater unit (take care not to disconnect coolant circulation), if necessary refer to Danger! Risk of injury and of scalding with high coolant temperature! Disconnect plug connection on heater unit. Connect voltage source to plug X6 (remove combustion air blower if necessary). | Combustion air blower does not run or runs loudly: Replace combustion air blower complete with connection cable and plug X6. Combustion air blower runs freely (no grinding noise etc.): Erase fault code, if fault code Ω re-appears when test running heater unit: Replace control unit (Z14) on trial. | |